Pioneer RS-232 Flat Panel Television User Manual


 
19
4.0 Precautions
1) If the power shuts down and stays OFF for a long period of time, an internal problem may have occurred (broken
part, etc.).
Turn OFF the main power switch on the plasma display then wait 1 to 2 minutes and try turning the power ON again.
If the power goes OFF again, the display requires service.
If the display operates normally, continue to use it.
2) When an image (still image, telop, etc.) is shown on the screen for a long period, there is a possibility that the
image could be burned in (not able to be removed). Manage this situation by making necessary changes in the
video software, projection method, system configuration, etc.
3) The following kinds of input signals could cause inferior image quality.
Video signal that has been dubbed (copied) repeatedly
Copyright-protected video signals
Scrambled cable TV signals
Signals with a sync signal and video signal that are extremely out of phase
4) The fan starts operating when the surrounding temperature is greater than 35 °C. The fan's rpm becomes faster as
the temperature increases; this is normal.
5) Screen-saver function (still image detection)
When an image having little to no motion such as a photograph or PC screen is displayed continuously, the brightness
slightly drops. To protect the plasma panel, the screen-saver function detects images with little to no motion then
automatically adjusts the brightness. This dimming is not an indication that the panel is failing.
Time until the screen-saver function operates:
Normal-operation mode/menu mode: Approximate 3 minutes after the power is turned ON or after the input is
switched.
7 Self-diagnosis Function
When there is an connection or operation error, a message displays on the screen. After reading the contents of the
error message, refer to the chart below before checking the unit.
Precautions
Error Message
CAUTION
OUT OF RANGE or
CAUTION
UNSUPPORTED SIGNAL or
SIGNAL NG
WARNING
THERMAL ALERT
SHUT DOWN (∗∗)
WARNING
FAN FAILURE
SHUT DOWN (∗∗)
ERROR
INVALID KEY ENTRY
SHUT DOWN (∗∗)
Remedy
The current signal input is not supported by the unit. Check the table of supported
input signals on pages 140 - 145 and change the output signal setting.
The current signal input is not supported when FRC is set to MODE2 or MODE3.
Check the FRC settings on page 208.
Turn OFF the main power.
Check whether the surrounding temperature is high.
If the cooling vents on the display are blocked, remove the obstacles blocking the
vents.
There is a problem with the fan. Immediately turn OFF the power and contact the
Pioneer service center or dealer.
An invalid operation was attempted. Check the input signals, connections and
settings.
Turn the main power OFF, wait 1 or 2 minutes and turn the power ON again. If the
problem still persists, remove the power plug from the outlet and contact a Pioneer
service center or dealer.
(∗∗): Numbers are displayed here.