Pioneer V5000 TV DVD Combo User Manual


 
DVD-V5000 DVD Player
RS-232 Command Protocol
4.1 Command Mnemonic
Each command is expressed as two (2) ASCII characters. There is no distinction
between uppercase and lowercase letters except when the Character strings are
in a PR command.
4.2 Argument
An Argument, expressed in either ASCII characters or ten digits, consists of
either an address or an integer. A Control Register uses an integer value to set a
specified value or condition.
If a command requires an argument, it is always placed before the command.
Example :
N
1
N
2
N
3
Minimum 000 ~ Maximum 300 (except MS command)
Minimum 000 ~ Maximum 2047 (Only MS command)
NOTE: If a command requires an argument but one is not supplied, the player
returns an error message.
An Address can be a Title, a Chapter, a Track, a Frame Number, or a Time Code
depending upon how the address flag is set. The Address must not exceed ten
characters and/or digits.
Address Type Media Type Format Range (Min-Max)
Title Number DVD N
1
N
2
1 ~ 99
Chapter Number DVD N
1
N
2
1 ~ 99
Frame Number DVD N
1
N
2
N
3
N
4
N
5
N
6
1 ~ 999999
DVD N
1
N
2
N
3
N
4
N
5
a
0 ~ 599:59
Time Code
CD/VCD N
1
N
2
N
3
N
4
b
0 ~ 99:59
Track Number CD/VCD N
1
N
2
1 ~ 99
Block Number CD N
1
N
2
N
3
N
4
N
5
N
6
c
0 ~ 995974
4.3 Command String
A command string consists of multiple commands on one line. The maximum
length of a command string is 32 characters. All command strings are terminated
by the Carriage Return <CR> code (0DH hex).
Example : FR2000SE 2300PL<CR>
NOTE: Assign the following commands individually.
Print Character [PR]
a
N
1
N
2
N
3
minutes N
4
N
5
seconds.
b
N
1
N
2
minutes N
3
N
4
seconds.
c
N
1
N
2
minutes N
3
N
4
seconds N
5
N
6
Block.
- 11