SW 1: Device Mode Selection
Position 1: DCE means the IC-485 is set at DCE
mode and it must be connected to a DTE
device.
Position 2: DTE means the IC-485 is set at DTE
mode and it must be connected to a DCE
device.
Position 3: Monitor means the IC-485S is set at
monitor mode and it is used to monitor
-____
4
User’s Manual
User’s Manual
INSTALLATION
IC-485S/IC-485SI
the RS-485 line signals (for
IC-485S
only).
SW2: Transmitting and Receiving mode selection
Position 1:
(TxON,
RxON)
means the IC-485 is
always in transmitting mode and in re-
ceiving mode.(using in Point-to-Point
mode)
Position 2:
(TxRTS,
RxRTS)
means the K-485 is in
transmitting mode while RTS signal is at
high level and it is in receiving mode
while RTS signal is at low level.(using
in Multidrop mode)
Position 3:
(TxRTS,
RxON)
means the IC-485 is
always in receiving mode and it is in
transmitting mode only while RTS sig-
nal is at high level.(using in Multidrop
mode to monitor the RS-485 line signals)