Runco CX-70DHD Flat Panel Television User Manual


 
Maintenance and Troubleshooting
58 CX-70DHD Installation/Operation Manual
PRE
L
IMINAR
Y
The CX-70DHD and DHD
Controller are both on, but
there is no picture and
on-screen menus do not
appear.
Faulty or incorrect video
connection between the
DHD Controller and the
CX-70DHD.
Ensure that the HDMI
output from the DHD
Controller is properly
connected to the
DVI IN
input on the CX-70DHD
(see Figure 3-4).
The display is on and menus
appear, but there is no
picture.
Incorrect source selection.
Source component is not
turned on.
Source component is
connected incorrectly or
not at all.
Select the correct source.
Turn on the source
component.
Check connections from
source component to DHD
Controller.
Image is too bright and/or
lacks definition in the bright
areas of the image.
Contrast is set too high. Lower the contrast setting.
Image appears “washed out”
and/or dark areas appear too
bright.
Brightness is set too high. Lower the brightness
setting.
Colors in the image are
swapped; for example, reds
appear blue or vice versa.
The Red/Pr, Green/Y or
Blue/Pb outputs from the
source are connected to
the wrong inputs on the
DHD Controller.
Ensure that the source
outputs are connected to
the correct DHD Controller
input.
RGB-HD images appear
“noisy.”
Tracking and Phase
settings need adjustment.
Adjust Tracking and Phase
settings (refer to Input
Position on page 45).
Computer images do not dis-
play correctly.
The resolution and
frequency of the video
card in the computer are
not compatible with the
CX-70DHD.
Select a compatible
resolution and vertical
frequency (refer to
Supported Timings on
page 70).
The image is too large or too
small.
Image size needs
adjusting.
Adjust the image size (refer
to
Input Position on
page 45 or Output Shift
on page 51).
Table 5-1. Troubleshooting Chart (continued)
Symptom Possible Cause(s) Solution