39
Video Input
To store the adjusted data, select Store and press the
SELECT button. Select a level from Image 1 to 4 with the
Point ed buttons and press the SELECT button. A
confirmation box will appear and then select [Yes].
Stored data can be called up by selecting "Image" in the
Image Level Selection on page 37.
Image Level Menu
Move the red framed pointer to
an image item to be set and
then press the SELECT button.
To reset the adjusted data, select Reset and press the
SELECT button. The confirmation box will appear and then
select [Yes]. All adjustments will return to their previous
figures.
Reset
Store
Exit the Image Adjust Menu.
Quit
✔
Note:
Progressive cannot be selected when 480p, 575p, 720p, 1035i, or
1080i is selected. (p36)
Store
item
Interlaced video signal can be displayed in a progressive
picture. Select one of the following.
Off...........disabled.
L1............Select “L1” for an active picture.
L2............Select “L2” for a still picture.
Film.........Select “Film” for watching a film. With this
function, the projector reproduces pictures
faithful to the original film quality.
Progressive
Noise reduction
Noise interference on the screen can be reduced. Select
one of the following to get smoother images.
Off...........disabled.
L1............lower reduction
L2............higher reduction
The confirmation box
will appear and then
select [Yes].
Video Input
Press the Point 7 8 buttons to obtain better balance of
contrast. (From 0 to 15.)
Gamma
Press the Point 7 button to soften the image and the Point
8 button to sharpen the image. (From 0 to 15.)
Sharpness