52
Maintenance and Cleaning
When the life of the projection lamp of this projector draws
to an end, the LAMP REPLACE indicator emits a yellow
light. If this indicator lights yellow, replace the lamp with a
new one promptly.
Follow these steps to replace the lamp.
Lamp
ORDER REPLACEMENT LAMP
Replacement lamp can be ordered through your dealer. When ordering a projection lamp, give the following
information to the dealer.
●
Model No. of your projector : PLC-XU73/ PLC-XU70
● Replacement Lamp Type No. : POA-LMP90
(for PLC-XU73)
(Service Parts No. 610 323 0726)
POA-LMP93 (for PLC-XU70)
(Service Parts No. 610 323 0719)
For continued safety, replace with a lamp of the
same type. Do not drop a lamp or touch a glass
bulb! The glass can shatter and may cause injury.
Allow a projector to cool, for at least 45 minutes
before you open the Lamp cover. The inside of
the projector can become very hot.
Top Control
CAUTION
Screw
Turn off the projector and disconnect the AC power
cord. Allow the projector to cool for at least 45
minutes.
Remove 2 screws of the lamp with a screwdriver and
pull out the lamp by grasping the handle.
1
3
Replace the lamp with a new one and tighten the 2
screws back into position. Make sure that the lamp is
set properly. Replace the lamp cover and tighten the
screw.
4
Remove the screw with a screwdriver, and remove
the lamp cover.
2
Connect the AC power cord to the projector and turn
on the projector.
6
Reset the lamp replacement counter.
See “Lamp Replacement Counter” on the next page .
5
Lamp Replacement
Handle
Screw
CAUTION
ON
- OFF
POWER
KEYSTONE
INPUT
WARNING
LAMP REPLACE
MENU
- VOLU
ME
+ VOLUME
SELECT
Screw
Lamp Cover
Do not open the little compartment.
This is used to service the projector.
WARNING:
TURN OFF THE UV LAMP BEFORE
OPENING THE LAMP COVER
This indicator is yellow when
the life of the projection lamp
draws to an end.