Seagate ST11950N/ND/W/WD Flat Panel Television User Manual


 
ST11950 and ST12550 Installation Guide, Rev. D 31
Figure 10b.Additional jumper options
for ST11950W/WD and ST12550W/WD drives
J4
RES
RES
PAR
Reserved for factory use.
Reserved (RES)
Enable motor start. This makes the drive wait 
for the Start Unit command from the host before 
starting the spindle motor.
Motor Start option (MTR)
Disable motor start (default). This causes the 
drive to start according to the Delay Motor 
Start option setting as described below.
J01
Pin 1
J4
MTR
DMS
WP
Enable parity check of SCSI bus data (default).
Parity Check option (PAR)
Disable parity check of SCSI bus data.
Motor start delay equal to the SCSI ID multiplied 
by 10 seconds. For example, if the SCSI ID = 2, 
the drive will delay for 20 seconds before starting.
Delay Motor Start option (DMS)
(valid only if the Motor Start option
jumper is not connected)
Disable the Delay Motor Start option (default).
Write Protect = On (disables writing).
Write Protect option (WP)
Write Protect = Off (enables writing – default).