Seagate ST11950N/ND/W/WD Flat Panel Television User Manual


 
ST11950 and ST12550 Installation Guide, Rev. D 43
Note. Signal ground on the power control board (PCB)
and the head and disc assembly (HDA) are con-
nected together in this drive and you cannot
separate them. The equipment in which you have
mounted the drive is connected directly to the
HDA and PCB without electrically isolating shock
mounts. Maximizing the conductive contact area
between HDA ground and system ground may
reduce radiated emissions. If you do not want the
system chassis to be connected to the HDA/PCB
ground, you must provide a nonconductive (elec-
trically isolating) method of mounting the drive in
the host system. This may increase radiated emis-
sions and is the system designer’s responsibility.
Hinweis:
Die Signalerde auf der Stromregelungskarte (PCB)
und der Kopf- und Festplatteneinheit (HDA) sind
in diesem Laufwerk miteinander verbunden und
können nicht getrennt werden. Das Gerät, in das
Sie das Laufwerk eingebaut haben, ist ohne
elektrisch isolierende Stoßdämpfer direkt an die
HDA und PCB angeschlossen. Die
elektromagnetische Strahlung kann reduziert
werden, indem Sie eine möglichst große leitende
Kontakfläche zwischen der HDA-Erdung und der
Systemerdung vorsehen. Wenn Sie das