Server Technology PP02 Universal Remote User Manual


 
DIP Switch Configuration
The following outlines the DIP switch positions for the Infinite-On/Off Mode. When the Infinite-On/Off option is
enabled, the 15 Ring Turn-OFF and +Aux Feature must also be enabled. Power can then be switched ON by 1, 5, or 10
RINGs and switched OFF with 15 RINGs. In all cases, the unit must first be 'primed' as described earlier.
Infinite-On/Off Mode Options
DIP switches 3 through 8, when set as follows, selects the Infinite-On/Off Mode:
3|OFF 4|OFF 5|ON 6|ON 7|ON 8|ON
DIP switches 1 and 2 select the Infinite-Power-ON Ring Number:
1|OFF 2|ON Infinite-ON after Ring One (1) *
1|ON 2|OFF Infinite-ON after Ring Five (5)
1|ON 2|ON Infinite-ON after Ring Ten (10)
In all cases, allowing 15 rings to occur will effect an Infinite-Power-OFF.
Example DIP Switch Configurations, Infinite-On/Off Mode: Switch-On/Stay-On, or
Switch-Off/Stay-Off
One RING to 'prime', wait 15 seconds;
2nd call: 1 RING to Infinite-ON
15 RINGs to Infinite-OFF
One RING to 'prime', wait 15 seconds;
2nd call: 5 RINGs to Infinite-ON
15 RINGs to Infinite-OFF
One RING to 'prime', wait 15 seconds;
2nd call: 10 RINGs to Infinite-ON
15 RINGs to Infinite-OFF
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
Remote Power On/Off Infinite-On/Off Mode 27