Sony BKDW-515 DVR User Manual


 
Menu List
A-40 Appendix
Appendix
K19
Item number
Function
PROCESS
CONTROL
Item
Selects the method for operating the internal digital video
processor.
0: Select this setting when using the optional BVR-50
Remote controller to remotely control the internal digital
video processor.
1: Select this setting when adjusting the settings of the
internal digital video processor through items 715 to 721.
2: Select this setting when controlling the internal digital
processor from the control panel of the VTR.
Note
Changing the PROCESS CONTROL setting during
playback may cause a momentary interruption in the sound
output.
Settable range
remote
[setupmenu]
local
0
[1]
2
Selects the audio input signal for the various channels.
0: Audio signal input to the ANALOG AUDIO INPUT
connectors.
1: Audio signal input to the SERIAL V/A INPUT connector.
2: Audio signal input to the AUDIO INPUT (AES/EBU)
connectors.
0
[1]
2
AUDIO INPUT SEL
CH-1
analog
[sif]
AES/EBU
0
[1]
2
analog
[sif]
AES/EBU
0
[1]
2
AUDIO INPUT SEL
CH-2
K22
analog
[sif]
AES/EBU
0
[1]
2
AUDIO INPUT SEL
CH-3
K23
analog
[sif]
AES/EBU
AUDIO INPUT SEL
CH-4
K24
K21
off
[on]
DOLBY NR
(DVW-A500/1 and
A500P/1)
K25
0
[1]
Turns on and off the Dolby NR (noise reduction) C system
which is used for cue audio tracks only when using an
oxide tape. The system automatically turns on when using
a metal tape.
0: Plays back an analog Betacam oxide tape without the
Dolby NR system.
1: Plays back an analog Betacam oxide tape with the
Dolby NR system.
[off]
on
[0]
1
K26 AUDIO EMPHASIS
Set to emphasize to a digital audio signal that has been
converted from an analog audio input signal.
This setting also allows you to emphasize while digitizing a
playback audio signal from a conventional Betacam
cassette.