5-8 Chapter 5 Recording/Playback
Chapter 5 Recording/Playback
5-3-4
Selecting the Conversion
Mode of the Effective Scanning Line
Number (when HKDV-502 is installed)
When the optional HKDV-502 HD Line Converter
Board is installed in the HDW-F500, to select the
conversion mode, follow the procedure below.
1 Press the MAINTENANCE switch using the tip of
a small pointed object.
2 Press the [F8](MAINTE EXEC) button while
holding down the SFT button.
3 Press the [F9](OTHERS CHECK) button.
4 Press the [F9](SYSTEM MENU) button.
5 Press the [F1](ACTIVE LINE) button to select the
conversion mode.
Pressing the button cycles the settings from 1035,
1080, off. off is used to activate the function to
improve the vertical resolution during slow-motion
playback.
1035: Convert the effective scanning line number
from 1080 to 1035.
1080: Convert the effective scanning line number
from 1035 to 1080.
6 Press the [F9](EXEC).
A message asking you to confirm the operation
appears in the display.
To cancel the execution
Press the [F8](CANCEL) button.
7 Press the [F9](EXEC).
The HDW-F500 is restarted automatically.
8 Press the SET UP button.
The VTR SETUP menu appears in the display.
CH.COND
MAINTENANCE
ROM
MAINT
PANEL
MAINT
SERVO
CHECK
A/V
CHECK
OTHERS
CHECK
RF
CHECK
DT/SAT
CHECK
EXIT
TCR 00:00:00:00
MAINTENANCE
OPERATION
DRUM RUNNING
THREADING
TAPE TRAVEL
529HOURS
34HOURS
20HOURS
780TIMES
[ 26H]
[ 16H]
[ 449H]
MAINTENANCE INFOMATION DISPLAY
OPERATION
CH.COND
MAINTE INFO
ERR
LOG
ROM
VER
MAINTE
EXEC
OPTION
INFO
EXIT
TCR 00:00:00:00
DRUM RUNNING
THREADING
TAPE TRAVEL
529HOURS
34HOURS
20HOURS
780TIMES
[ 26H]
[ 16H]
[ 449H]
OPERATION INFO
FREQ: 59.94i
LINE:1080 1035(CONV)
i
OTHERS CHECK
CH.COND
OTHERS CHK
MEMORY
CHECK
NVRAM
CTL
RS232C
STATUS
M-HEAD
ROOM
HOURS
METER
PAPA-I
SETUP
PAPA-O
SETUP
SYSTEM
MENU
EXIT
TCR 00:00:00:00
5-3 Preparing for Playback
[F1]1080 1035 (CONVERT)
CH.COND
SYSTEM MENU
SYSTEM
FREQ
ACTIVE
LINE
D-CONV
SDI
EXIT
EXEC
CANCEL
[F2]SYSTEM FREQUENCY
[F8]Cancel
[F3]SDI OUT. ( D1 / D2 )
[F4]META DATA(FILM/C.C./USER)
SYSTEM MENU
[F9]Execute of Reset VTR System.
with conditions
STOP & not STANDBY
EJECT Tape.
off
MODE7
D1
META
DATA
FILM
MODE7 59.94i