Sony KV-T29SN81 CRT Television User Manual


 
– 19 –
KV-T29SN81
RM-870
Entering service mode
With the unit on standby
DISPLAY
5
VOL (+)
POWER
The operation sequence puts the unit into service mode.
SECTION 4
CIRCUIT ADJUSTMENTS
4-1. ADJUSTMENTS WITH COMMANDER
Service adjustments are made with the RM-870 that comes with
this unit.
[1], [4] Raise/lower the service item number
[3], [6] Raise/lower the data
[MUTING] Writes
[0] Executes the writing
[7], [0] The data all becomes the values in memory
[8], [0] User control all goes to the standard state
[5], [0] Service data initialization (Be sure not to use
usually.)
[2], [0] Write 50Hz adjustment data to 60Hz, or
viceversa.
The screen display is :
[1], [4] Select the adjustment item.
[3], [6] Raise/lower the data.
[MUTING] Writes
[0] Executes the writing.
MUTING
TEXT
VIDEO
HOLD
TV
TEXT CLR
+ SELECT
PIC MODE
A/B
ENLARGE
WAKE UP
INDEX
VOL
PROGR
SLEEP
+
1 2 3
4 5 6
7 8 9
0
DISPLAY
REVEAL
POWER
+
÷
SERVICE Mode08
DATA
RGB
50 Depends on the signals
PAL, SECAM : 50
NTSC : 60
10000000
Adjustment item
00
Item number
RM-870