Menu items in the range 600 to 699, relating to the time code generator (Continued)
Menu items in the range 700 to 799, relating to video control
Item number Item name
Settings
606 TC OUTPUT SIGNAL IN
REGEN MODE
Select the signal output from the TIME CODE OUT connector during playback at
normal (×1) speed.
TAPE: The playback time code signal is output without regeneration. (The time
code values do not correspond to the video output.)
REGEN : The playback time code is output after regeneration.
705
Item number
Item name
Settings
703 BLANK LINE SELECT Switch blanking on or off for individual lines in the vertical blanking interval. The
Y/C signal and odd/even fields are blanked simultaneously.
Note
For playback of an analog Betacam cassette (Betacam SP, etc.) regardless of the
setting of this item, the chrominance signal is blanked up to line 15.Sub-Item
0 ALL LINE - - - : Specify the blanking for each line separately.
BLANK: Regardless of the setting of other sub-items, blank all lines which can be
specified in this menu item.
THROU: Regardless of the setting of other sub-items, switch off blanking for all
lines which can be specified in this menu item.
12 ...
19
LINE 12 ... LINE
19
In 525-line
mode
Specify blanking for lines 12 to 19.
BLANK : Carry out blanking.
THROU: Switch off blanking.
In 625-line
mode
23 LINE 23 Specify blanking for line 23.
HALF : Carry out half-blanking.
THROU: Switch off blanking.
9 ...
22
LINE 9 ... LINE 22 Specify blanking for lines 9 to 22.
BLANK : Carry out blanking.
THROU: Switch off blanking.
EDGE SUBCARRIER
REDUCER MODE
During playback of a composite signal, in the playback circuit the edge subcarrier
reducer (ESR) is automatically switched on or off according to the VTR
operation. When recording a Non-Standard signal, for example, if the color
edges are not as good as with a proper signal, the ESR can be forced on. This
item makes this selection.
AUTO : ESR is switched on and off automatically.
ON: ESR operation is forced on.
20 LINE 20 Specify blanking for lines 20.
BLANK : Carry out blanking.
HALF: Carry out half-blanking.
THROU: Switch off blanking.
(Continued)