Sony MSW-M2100P VCR User Manual


 
Chapter 8
Setup Menus
Chapter 8
Setup Menus 8-17
Menu items in the range 800 to 899, relating to audio control (Continued)
Item number
Item name
Settings
806
LEVEL METER SCALE
Select the mode in which digital audio levels are displayed.
PEAK.0 : Displays the audio level as negative values with the maximum level set
to 0 dB.
REF.0: Displays the audio level as positive and negative values with the
reference level set to 0 dB.
809 AUDIO LEVEL METER
DIMMER CONTROL
Set the brightness of the audio level meters.
0 ... 7: Set in this range. 0 is the brightest, and 7 the dimmest.
807 AUDIO OUTPUT PHASE Select the output timing of digital audio playback signals: (SDI and AES/EBU
only). The reference position corresponds to a setting of 80H; when the setting
is less than 80H, the output timing is advanced, and when it is higher than 80H,
the output timing is delayed. (at 80H, 128 samples = approx. 2.7 ms, and 1
sample=approx. 20 µs)
0 ... 80 ... FF : Setting in this range
808 INTERNAL AUDIO
SIGNAL GENERATOR
Select the operation of the internal audio test signal generator.
OFF : No operation
SILNC: Silent signal
1KHZ: At 1 kHz, 20 dB FS sine wave is supplied to all audio input channels.
824 ANALOG OUTPUT
SELECT
Select the analog audio signals (tracks 1 to 8) to be assigned to audio output
channels 1 to 4.
Sub-item
1 CH1/CH2 tr1/2 : Tracks 1 and 2 assigned to audio output channels 1 and 2
tr3/4: Tracks 3 and 4 assigned to audio output channels 1 and 2
tr5/6: Tracks 5 and 6 assigned to audio output channels 1 and 2
tr7/8: Tracks 7 and 8 assigned to audio output channels 1 and 2
2 CH3/CH4 tr1/2: Tracks 1 and 2 assigned to audio output channels 3 and 4
tr3/4 : Tracks 3 and 4 assigned to audio output channels 3 and 4
tr5/6: Tracks 5 and 6 assigned to audio output channels 3 and 4
tr7/8: Tracks 7 and 8 assigned to audio output channels 3 and 4
823 NAU FLG PB Controls the non-audio flag when the playback format is Digital Betacam or
Betacam SX.
Sub-item
1 CH1/CH2 During playback (except E-E mode), sets the digital audio non-audio flag as
follows.
OFF : OFF (the data is audio)
ON: ON (the data is non-audio)
AUTO: As follows, depending on whether tape data has been confirmed.
Tape data has been read and confirmed: ON or OFF, according to the data.
Tape data has not been confirmed: Current state is maintained.
Notes
In the Betacam SX format, audio signals only are recorded. Therefore, the non-
audio flag is OFF.
During playback of analog tapes, the non-audio flag is OFF regardless of the
setting of this item.
In the MPEG IMX format, the non-audio flag follows the setting of maintenance
menu item M372 during recording, playback, and E-E mode.
For more information about the maintenance menu item M372, refer to the
Maintenance Manual.
2 CH3/CH4