Chapter 6: Advanced Chassis Setup
6-9
6-5 Power Supply
The SuperServer 6015B-3/6015B-T has a single 560 watt power supply, which is
auto-switching capable. This enables it to automatically sense and operate at a
100v to 240v input voltage. An amber light will be illuminated on the power supply
when the power is off. An illuminated green light indicates that the power supply
is operating.
Power Supply Failure
If the power supply unit fails, the system will shut down and you will need to replace
the unit. Replacement units can be ordered directly from Supermicro (see contact
information in the Preface). As there is only one power supply unit in the 6015B-
3/6015B-T, power must be completely removed from the server before removing
and replacing the power supply unit for whatever reason.
Removing/Replacing the Power Supply
1. Removing the power supply
First unplug the power cord from the failed power supply module. To remove the
failed power module, fi rst locate and remove the two screws on the inner side of
the power supply module that secures it to the chassis. Next, push the release tab
(on the back of the power supply) to the right and then pull the module straight out
(see Figure 6-6). The power supply wiring was designed to detach automatically
when the module is pulled from the chassis.
2. Installing a new power supply
Replace the failed power module with another PWS-561-1H20 power supply mod-
ule. Simply push the new power supply module into the power bay until you hear
a click. Secure it to the chassis with the two screws that were previously removed.
Finish by plugging the AC power cord back into the module.