Vizio VS-900 Universal Remote User Manual


 
TOA VS-900 Programmer’s Guide
12
Start of Normal Conversation
Field Name Length
(Bytes)
Value Description Direction
DLE
1 10H Delimiter
ENQ
1 05H Enquiry
VS-900 to PC
DLE
1 10H Delimiter
ACK
1 06H Acknowledge
PC to VS-900
DLE
1 10H Delimiter
STX
1 02H Start Of Text
Log Data
1 6FH Log Data
Exchange #
2 30H 31H Exchange # “01”
Time
(HH:MM:SS)
6 31H 36H 33H 37H 32H
37H
Time: “16:37:27"
Line #1
6 32H 30H 30H 20H 20H
20H
Calling Station # “200”
Line #2
6 31H 30H 35H 20H 20H
20H
Called Station # “105”
Line #3
6 20H 20H 20H 20H 20H
20H
Hold Station # (Blank)
Line #4
6 20H 20H 20H 20H 20H
20H
Not Used (Blank)
Status #
2 31H 30H
“10” (Start of normal
conversation)
DLE
1 10H Delimiter
ETX
1 03H End Of Text
BCC
1 74H Block Check Character
VS-900MF to PC
DLE
1 10H Delimiter
ACK
1 06H Acknowledge
PC to VS-900
DLE
1 10H Delimiter
EOT
1 04H End of Transmission
VS-900MF to PC
Normal Call Termination
Field Name Length
(Bytes)
Value Description Direction
DLE
1 10H Delimiter
ENQ
1 05H Enquiry
VS-900 to PC
DLE
1 10H Delimiter
AC
K
1 06H Acknowledge
PC to VS-900
DLE
1 10H Delimiter
STX
1 02H Start Of Text
Log Data
1 6FH Log Data
Exchange #
2 30H 31H Exchange # “01”
Time (HH:MM:SS)
6 31H 36H 33H 37H 32H 38H Time: “16:37:28"
Line #1
6 32H 30H 30H 20H 20H 20H Calling Station # “200”
Line #2
6 31H 30H 35H 20H 20H 20H Called Station # “105”
Line #3
6 20H 20H 20H 20H 20H 20H Not Used (Blank)
Line #4
6 20H 20H 20H 20H 20H 20H Not Used (Blank)
Status #
2 33H 32H
“32” (Normal call
termination)
DLE
1 10H Delimiter
ETX
1 03H End Of Text
BCC
1 73H Block Check Character
VS-900MF to PC
DLE
1 10H Delimiter
AC
K
1 06H Acknowledge
PC to VS-900
DLE
1 10H Delimiter
EOT
1 04H End of Transmission
VS-900MF to PC