TOA VS-900 Programmer’s Guide
9
2. Remote Dialing – All Call Paging
The data sequence below will remote dial Master Station #2 in Exchange #3 to initiate All-Call Paging by
dialing *800#. Again, the “CC” (Clear) is included to terminate any current Master Station functions.
Note: The total Dialing Contents must be 32 bytes.
Field Name Length
(Bytes)
Value Description Direction
DLE
1 10H Delimiter
ENQ
1 05H Enquiry
PC to VS-900MF
DLE
1 10H Delimiter
ACK
1 06H Acknowledge
VS-900MF to PC
DLE
1 10H Delimiter
STX
1 02H Start Of Text
Remote Dial
1 4EH Remote Dialing Request
Exchange #
2 30H 33H EXCHANGE # "03"
Master Station #
1 32H MASTER # "2"
Dialing Contents
32 Bytes 43H 43H 2AH 38H 30H 30H
23H 20H 20H 20H 20H 20H
20H 20H 20H 20H 20H 20H
20H 20H 20H 20H 20H 20H
20H 20H 20H 20H 20H 20H
20H 20H
"CC*800#"
DLE
1 10H Delimiter
ETX
1 03H End Of Text
BCC
1 7DH Block Check Character*
PC to VS-900MF
DLE
1 10H Delimiter
ACK
1 06H Acknowledge
VS-900MF to PC
DLE
1 10H Delimiter
EOT
1 04H End of Transmission