Yamaha PLG100-DX Home Theater Server User Manual


 
42
Appendix
2.1.4.2 PLG100-DX Part Parameter Change
This message sets the PLG100-DX MULTI PART block (see Tables <2-1> and
<2-3>).
2.1.5 DX Parameter Change
11110000 F0H Exclusive status
01000011 43H YAMAHA ID
0001nnnn 1NH N:Device Number
0ggggghh GGH Parameter Group No.
0ppppppp PPH Parameter No.
0vvvvvvv VVH Data
11110111 F7H End of Exclusive
2.1.5.1 VCED parameter change
This message sets the VCED block (see Tables <3-1> and <3-2>).
2.1.5.2 ACED parameter change
This message sets the ACED block (see Tables <3-1> and <3-3>).
2.2 Bulk dump
This device uses only the following bulk dump messages.
[XG BULK DUMP]
1) XG System bulk dump
2) Multi Part bulk dump
[PLG100-DX NATIVE BULK DUMP]
1) System bulk dump
2) Part bulk dump
[DX BULK DUMP]
1) VCED
2) ACED
3) VMEM
4) AMEM
2.2.1 XG bulk dump
This message sets XG-related parameters. Unlike parameter change messages,
a single message can modify multiple parameters. The message format is as
follows.
11110000 F0H Exclusive status
01000011 43H YAMAHA ID
0000nnnn 0NH N:Device Number
01001100 4CH Model ID
0sssssss SSH ByteCountMSB
0ttttttt TTH ByteCountLSB
0ggggggg GGH Address High
0mmmmmmm MMH Address Mid
0lllllll LLH Address Low
0vvvvvvv VVH Data
: :
0kkkkkkk KKH Check-sum
11110111 F7H End of Exclusive
Address and Byte Count are given in tables <1-n>. Byte Count is indicated by
the total size of the Data in tables <1-n>.
Bulk dump is received when the beginning of the block is specified in “Ad-
dress”.
‘Block’ indicates the unit of the data string that is indicated in tables 1-n as
‘Total size’.
Check sum is the value that produces a lower 7 bits of 0 when the Start Address,
Byte Count, Data, and the Check sum itself are added.
2.2.1.1 XG System bulk dump
This message sets the XG SYSTEM block (see Tables <1-1>, <1-2>).
2.2.1.2 Multi Part bulk dump
This message sets the MULTIPART block (see Tables <1-1>, <1-3>).
2.2.2 PLG100-DX Native Bulk Dump
This message sets the special parameters for PLG100-DX. Unlike Parameter
change, one message can modify multiple parameters.
11110000 F0H Exclusive status
01000011 43H YAMAHA ID
0000nnnn 0NH N:Device Number
01100010 62H Model ID
0sssssss SSH ByteCountMSB
0ttttttt TTH ByteCountLSB
0ggggggg GGH Address High
0mmmmmmm MMH Address Mid
0lllllll LLH Address Low
0vvvvvvv VVH Data
: :
0kkkkkkk KKH Check-sum
11110111 F7H End of Exclusive
The details are the same as for 2.2.1 XG Bulk Dump. However, see Tables <2-
n> for the Address, Byte Count, and block.
2.2.2.1 PLG100-DX System Bulk Dump
This message sets the PLG100-DX SYSTEM block (see Tables <2-1>, <2-2>).
2.2.2.2 PLG100-DX Multi Part bulk dump
This message sets the PLG100-DX MULTI PART block (see Tables <2-1>, <2-
3>).
2.2.3 DX bulk dump
11110000 F0H Exclusive status
01000011 43H YAMAHA ID
0000nnnn 0NH N:Device Number
0ttttttt TTH Format No.
0sssssss SSH ByteCountMSB
0ttttttt TTH ByteCountLSB
0vvvvvvv VVH Data
: :
0kkkkkkk KKH Check-sum
11110111 F7H End of Exclusive
Address and Byte Count are given in tables <3-n>. Byte Count is indicated by
the total size of the Data in tables <4-n>.
Bulk dump is received when the beginning of the block is specified in “Ad-
dress”.
“Block” indicates the unit of the data string that is indicated in tables 3-n as
“Total size”.
Check sum is the value that produces a lower 7 bits of 0 when the DATA, and
the Check-sum itself are added.
2.2.3.1 VCED Bulk Dump
This message sets the VCED block (see Tables <4-1> and <3-2>.
2.2.3.2 ACED Bulk Dump
This message sets the ACED block (see Tables <4-1> and <3-3>.
2.2.3.3 VMEM Bulk Dump
This message sets the VMEM block (see Tables <4-1> and <4-2>.
2.2.3.4 AMEM Bulk Dump
This message sets the AMEM block (see Tables <4-1> and <4-3>.
3. Realtime Messages
3.1 Active Sensing
a) Send
Do not send.
b) Receive
After FE is received one time, if the MIDI signal does not come within 400
msec, PLG100-DX will act the same as when ALL SOUND OFF, ALL NOTE
OFF, and RESET ALL CONTROLLERS are received, and return to the condi-
tion where FE has not been received once.
<1-1>
Parameter Base Address
MODEL ID = 4C
Parameter
Address
Description
(H) (M) (L)
XG SYSTEM 00 00 00 System
00 00 7E XG System On
00 00 7F All Parameter Reset
MULTI PART 08 00 00 Multi Part 1
:
08 0F 00 Multi Part 16
MULTI PART 0A 00 00 Multi Part 1
(additional) :
:
0A 0F 00 Multi Part 16
PART ASSIGN 70 02 00 PLG100-DX Part Assign