2-12 Copyright 1999, 3M IPC. All rights reserved.
4. Check the Box Centering Pressure gauge on the
Pneumatic Control Panel. Refer to Figure 2-15.
The gauge should read 40 60 PSIG. If the
pressure does not fall within this range, adjust the
pressure regulator (CW increases pressure,
CCW decreases pressure).
5. Check the Side Belt Pressure gauge on the
Pneumatic Control Panel. The gauge should read
40 60 PSIG. If necessary, adjust the Side Belt
Pressure Regulator to this setting. (CW in-
creases pressure, CCW decreases pressure).
6. Check the Paddle Pressure gauge on the Pneu-
matic Control Panel. The gauge needle should be
at 7 PSIG. Adjust as needed.
7. Check the Counter-Balance Pressure gauge on the
Pneumatic Control Panel. The gauge should read
40 60 PSIG. If the pressure does not fall within
this range, adjust the pressure regulator (CW
increases pressure, CCW decreases pressure).
Figure 2-15. Pneumatic Control Panel
Installation 3M-Matic 800rf Case Sealer