logo

2 Issue 1, August 2003 61182210L1-5A
Factory default restoration via VT100 menu screens
or SNMP commands
Firmware upgrade using YModem or TFTP
connection
Receives remote NTU’s firmware upgrades via
YModem or TFTP connection
Automatically updates the Circuit ID
Automatically updates the date and time registers
Password protected
See Figure 2 for a typical configuration setup.
Connections
The SHDSL T1/E1 LTU inserts into any access module
slot (1 through 28) of a Total Access 3000 chassis.
Power and alarm signals are provided to the module
through the backplane of the chassis.
The G.703 and SHDSL signals are transmitted/received
via the 64-pin backplane amphenol connectors. The
G.703 signal is transmitted to the network side via “Pair
8,” and the G.703 signal is received from the network
side via connector “Pair 7.” The SHDSL signal is trans-
mitted to and from the customer side via connector
“Pair 2.”
Compliance
Table 1 shows the compliance codes for the SHDSL T1/
E1 LTU. The SHDSL T1/E1 LTU is NRTL listed to the
applicable UL standards. The SHDSL T1/E1 LTU is to
be installed in a restricted access location and in a Type
“B” or “E” enclosure only.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received,
including interference that may cause undesired
operation.
Changes or modifications not expressly approved by
ADTRAN could void the user’s authority to operate this
equipment.
3. INSTALLATION
After unpacking the SHDSL T1/E1 LTU, inspect it for
damage. If damage has occurred, file a claim with the
carrier, then contact ADTRAN Customer Service.
Refer to the Warranty and Customer Service section for
further information. If possible, keep the original
shipping container for returning the SHDSL T1/E1
LTU for repair or for verification of shipping damage.
Figure 2. Typical System Application
Table 1. Compliance Codes
Code Input Output
Power Code (PC) F C
Telecommunication Code (TC) X
Installation Code (IC) A
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Network
Management
System
VT100
VT100
Total Access 3000
SHDSL
T1/E1
LTU
SHDSL
T1/E1
NTU
1BASCU 2 345678 910 1112 1314 1516 1718 1920 2122 2324 2526 2728
SCU
FSE
MODE
ALM
HST
ACO
C
R
A
F
T
ACO
SELECT
1181018L1
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
2
1
P
O
R
T
PWR
3
4
LTU
1181308L1
OPT
Customer T1 or E1
Equipment
(e.g., PABX)
1225236L1
T1/E1
SHDSL
PWR
TEST
ALM
SHDSL
NTU
2-Wire Twisted Pair