![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/c/a4/ca451e3a-f4c4-7c74-7558-89aaba92c4bb/ca451e3a-f4c4-7c74-7558-89aaba92c4bb-bg7.png)
61182210L1-5A Issue 1, August 2003 7
Table 4. Configuration Options List
Category Option Setting Default
Unit Options Data Mode For Data Type = T1, Data Rate can
be from 3 to 24 timeslots
(i.e. 200 kbps to 1.544 Mbps)
For Data Type = E1, Data Rate can
be from 3 to 32 timeslots
(i.e., 192 kbps to 2.048 Mbps)
Data Type = 1
Data Rate = 24
Local Management 1 = Disabled
2 = Enabled
Enabled
Clock Source 1 = Internal
2 = External
Internal
Service State 1 = In Service
2 = Out of Service - Unassigned
3 = Out of Service - Maintenance
Out of Service -
Maintenance
External Port Alarms 1 = Disabled
2 = Enabled
Disabled
Restore Factory Defaults
Firmware Upgrade
Change Password
SHDSL Options SES CVC Threshold 0 to 255 CVC’s 50
SNR Margin Alarm
Threshold
0 = Disabled
1 to 15db = Alarm Threshold
Disabled
Loop Attenuation Alarm
Threshold
0 = Disabled
1 to 127db = Alarm Threshold
Disabled
ES 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 Seconds = Alarm Threshold
Disabled
SES 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 Seconds = Alarm Threshold
Disabled
UAS 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 Seconds = Alarm Threshold
Disabled
CVC 15 Minute Alarm
Threshold
0 = Disabled
1 to 65535 Errors = Alarm threshold
Disabled
LOSWS 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 Seconds = Alarm Threshold
Disabled
T1 Options (T1 Mode Only) Line Coding 1 = AMI
2 = B8ZS
B8ZS
Framing Mode 1 = Unframed
2 = SF
3 = ESF
ESF
Idle Pattern 00h to FFh 7Fh
FDL Monitoring (ESF Mode
Only)
1 = Disabled
2 = Enabled
Disabled