![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/9/e6/9e6af14c-69cc-e0d4-8def-54d92e1e8ac6/9e6af14c-69cc-e0d4-8def-54d92e1e8ac6-bg9f.png)
Menu Descriptions
61179641AL1-5C 5-107
E1 Status Menu
E1 Status
Main Menu\Network Port\E1 Main Menu\E1 Status\
The E1 Status Menu (see Figure 5-71) displays the status of the E1 network circuits and a
summary of the associated alarm counts.
Figure 5-71. E1 Status Menu
The E1 Status menu options are shown in Table 5-73.
Table 5-73. E1 Status Menu Options
Option Field Function
N/A Framing This field displays the framing setting for the E1 circuit.
For more information, see Table 5-72 on page 5-106.
N/A Line Code This field displays the line code setting for the E1
circuit. For more information, see Table 5-72 on page 5-
106.
N/A E1 Alarm This field indicates if there are any E1 alarms.
N/A Total Alarms Red This field indicates the number of Loss of Signal (Red)
alarms.
N/A Total Alarms Yellow This field indicates the number of Receive Remote Alarm
Indication (Yellow) alarms.
N/A Total Alarms Blue This field indicates the number of Receive Alarm
Indication Signal (Blue) alarms.
8 Reset Alarm Counts This option is used to clear all the E1 status alarm
fields.
TID: TA1248 Total Access 1248 MM/DD/YY HH:MM
Unacknowledged Alarms: None
E1 Status
1 2 3 4
Framing FAS+CRC FAS+CRC FAS+CRC FAS+CRC
Line Code HDB3 HDB3 HDB3 HDB3
E1 Alarm RED RED RED RED
Total Alarms
Red 2 2 2 2
Yellow 0 0 0 0
Blue 0 0 0 0
8. Reset Alarm Counts Cleared:
Selection :
'?' - System Help Screen