![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/1/a8/1a81fce0-40c0-4151-9b01-6b63a643eb3c/1a81fce0-40c0-4151-9b01-6b63a643eb3c-bg1c.png)
4600 Series IP Telephone Installation Guide
Static Addressing Installation
3-6
where dd is the value of the Differential Services signaling parameter.
7. Enter a valid value (between 0 and 63) for the new value of the Differential Services signaling
parameter.
If no new values were entered during this procedure, the following text is displayed left-
justified at the top of the display:
Press # to terminate the procedure.
If new values were entered during this procedure, the following text is displayed left-justified at
the top of the display:
Press the * button to terminate the procedure, or the # button to save the new values. If you
press the # button, the following text is displayed:
The new values are saved, and the user interface is restored to its previous state.
Secondary Ethernet (Hub) Interface Enable/Disable
3
Use the following procedure to enable or disable the hub interface.
1. While the phone is on-hook and idle, press the following sequence of keys on the faceplate of
the telephone:
Hold 4 6 8 # (Hold I N T #)
One of the following texts is displayed left-justified at the top of the display, depending on the
current value of the hub:
2. Press the 1 or 0 button to enable or disable the hub interface respectively, or the # button to
leave the current value.
No new values.
#=OK
Save new values?
*=no #=yes
New values
being saved
The default for the hub interface is enabled.
If HUB=enabled: HUB=enabled
0=disable #=OK
If HUB=disabled: HUB=disabled
1=enable #=OK