ClearCube F6151 Media Converter and Chassis System
User’s Guide 11
• First, disconnect the converter from the power. Then toggle
Pin 2 of the DIP switch to the up position to enable the forced
mode for TX port.
NOTE Pin 2 must be toggled up prior to speed and duplex
mode settings manually.
• Toggle down Pin 3 to force the TX port at the speed of
100Mbps. Or toggle up Pin 3 for 10Mbps speed.
• Toggle down Pin 4 to force the TX port at full duplex mode.
Or toggle up Pin 4 for half duplex mode.
• Toggle down Pin 5 to force the FX port at full duplex mode.
Or toggle up Pin 5 for half duplex mode.
• Connect the converter to the power again. The new setting will
come into effect then.
Front Panel & LEDs
LED INDICATORS
The LED indicators give you instant feedback on status of the
converter:
LEDs State Indication
Steady Power on
PWR stands for POWER
PWR
Off Power off
Steady Connection at the speed of
100Mbps
100 (Mbps)
Off Connection at the speed of 10Mbps
Steady A valid network connection
established
LNK stands for LINK
LNK/ACT
Flashing Transmitting or receiving data
ACT stands for ACTIVITY