11
ALIGNMENT INSTRUCTIONS
•
Select Subbrightness item, adjust Subbrightness data value
to obtain normal
brightness level.
•
Press the DISPLAY button to memorize the data.
CONTRAST
•
Fixed value = 20
TINT
•
Fixed value = 32
COLOR
•
Fixed value = 32
7) FACTORY OUTGOING MODE (S12 : FACT)
•
If you select the S12, then the set becomes factory outgoing status.
•
You can see the OSD “outgoing OK”
6) DIGITAL PRESET(D.P) ADJUSTMENTS(S9)
SUBBRIGHTNESS ADJUSTMENT
•
Receive a good local channel.
•
Enter the service mode and select service adjustment S9.
•
You can see the OSD as shoown in below.
D.P.
SUB BRIGHTNESS 64
CONTRAST 20
TINT 32
COLOR 32
MOVE ADJUST RECALL : SET
5) WHITE BALANCE ADJUSTMENT(S8)
•
Receive a good local channel.
•
Enter the service mode and select service adjustment S8.
•
You can see the OSD as shown in below.
•
Using volume up or volume down, adjust service adjustment data of RD/GD/BD and RB/GB/BB until a good gray
scale with normal whites is obtained.ALIGNMENT INSTRUCTIONS
•
Press the DISPLAY button to memorize the data.
RD 58
GD 10
BD 65
RB 105
GB 127
BB 100
MOVE ADJUST RECALL : SET