Graco 312374J Universal Remote User Manual


 
Integrated Air Controls
4 312374J
Replace Director Valve
Numbers in parentheses refer to F
IG
. 5.
1. Relieve pressure.
2. Remove screws (4a) and take off director valve.
3. Remove spring (4c), valve plate (4d), and o-ring
(4b)
.
4. Remove and discard pin (4g) and four valve seats
(4e) with o-rings (4f).
5. Insert new valve seats (4e) with o-rings (4f) and new
pin.
6. Insert new director valve plate (4d, see Note above)
spring (4c), and o-ring (4b).
7. Attach new director valve with screws (4a). Tighten
screws until snug.
Replace Air Motor Regulator
Numbers in parentheses refer to Parts, page 11. Air
motor regulator not included with 24C824 integrated air
controls.
1. Relieve pressure.
2. Disconnect air motor hosing and fittings.
3. Remove two screws (9) and take off the shutoff
valve (3) at top of module. If your supply system has
an air solenoid, it can remain attached to the shutoff
valve.
4. Remove two screws (9) and take off the air motor
regulator (6).
5. Attach new regulator to manifold. Orient so the
gauge lines up with the gauge on the ram air regula-
tor and the direction of flow arrow points up. Tighten
screws until snug. Recommend using thread locker
Loctite 220 or equivalent.
6. Reattach shutoff valve (3) at top of regulator. Make
sure that o-ring (5) is in place on valve (3).
F
IG
. 4
Note the orientation of the director valve plate when
you remove it. The opening should be on the oppo-
site side (left) of the lever.
r_289105_312375_4a
F
IG
. 5
4
4a
4b
4c
4d
4e
4f
4g
ti10952a