Graco 312374J Universal Remote User Manual


 
2-Button Interlock
8 312374J
See F
IG
. 13 for steps 9 - 14.
9. Inside 2-button interlock module, disconnect elbow
fitting (6) and push fittings (7) from tee fitting (5).
Remove plug (8) from auxiliary air supply port on
back of integrated air controls. Install tee fitting (5)
through into the port and through the opening in the
bracket. Reconnect elbow fitting (6) and push fit-
tings (7). Reinstall plug (8) at top of tee fitting (5).
10. Connect tubing (147) from ram down fitting on back
of air controls to fitting (D1) on right side of bottom
pilot valve. See F
IG
. 13.
11. Connect tubing from ram down fitting near top of
ram cylinder to fitting (D2) on left side of bottom pilot
valve. See F
IG
. 13.
12. Connect tubing (147) from ram up fitting on back of
air controls to fitting (U1) on right side of top pilot
valve. See F
IG
. 13
13. Connect tubing from ram up fitting near bottom of
ram cylinder to fitting (U2) on left side of top sole-
noid.
14. Connect blowoff air (B1) to blowoff air connector on
platen.
15. Replace cover on 2-button interlock assembly.
16. Attach all other hoses and replace shrouds.
It may be necessary to rearrange tubing so cover
will fit back on assembly.
F
IG
. 13
5
6
7
8
U1
U2
S1
D1
D2
S2
D1
(ram down)
U1
(ram up)
B1
(blowoff)