Grundig 32 VLE 8131 WF TV Antenna User Manual


 
59
ENGLISH
Additional Information for units
sold in the UK.
Units sold in the UK are suitable for operation
from a 240V ac, 50Hz mains supply.
The range of multi-system receivers is built to
work in most European countries. However, the
mains plug and socket system for the UK differs
from many European countries.
This appliance has been supplied with a fitted,
non-removable, approved converter plug for use
in the UK. This converter plug is fitted with a 5A
rated fuse.
In case this appliance is supplied with a moulded
2-pin Euro plug only, which is unsuitable for UK
operation, this must be cut off and immediately
disposed of. An approved 13A, 3-pin UK plug
should then be fitted by a qualified electrician.
Note:
7
The severed Euro plug must be destroyed
to avoid a possible shock hazard should it
be inserted into a socket elsewhere.
If a non-rewireable 3-pin plug or a rewireable
13A (BS1363) 3-pin plug is used, it must be fitted
with a 5A ASTA or BSI approved BS1362 fuse.
If any other type of plug is used it must be pro-
tected by a 5A fuse either in the plug, or at the
distribution board. If this type of plug becomes
defective, ensure that the fuse is removed before
disposal, to eliminate potential shock hazard.
If it is necessary to change the fuse in the non-
rewireable plug, the correct type and rating (5A
ASTA or BSI approved BS1362) must be used
and the fuse cover must be refitted. If the fuse
cover is lost or damaged, the lead and plug must
not be used until a replacement is obtained. Re-
placement fuse covers should be obtained from
your dealer.
Important:
7
The wires in the mains lead are colour
coded in accordance with the following
code:
BLUE – NEUTRAL
BROWN – LIVE
As the colours of the wires in the mains lead of
your appliance may not correspond with the col-
oured marking identifying terminals in your plug,
proceed as follows:
Connect the BLUE coloured wire to plug terminal
marked with the letter “N” or coloured black.
Connect the BROWN coloured wire to the plug
terminal marked with the letter “L” or coloured
red.
In no circumstance must any of the wires be con-
nected to the terminal marked with the letter “E”,
earth symbol “V”, coloured green, or green &
yellow.
INFORMATION
---------------------------------------------------------------------------------------------------------------------