HP (Hewlett-Packard) DL120 Home Theater Server User Manual


 
System Unit
Dimensions
(H x W x D)
(with bezel)
4.32 x 44.81 x 70.0 mm (1.69" x 17.64" x 27.56")
Weight
(approximate)
Maximum
(four hard drives, power
supply, and processor
installed)
31.49 lb (14.3kg)
Minimum
(one hard drive, power
supply, and processor
installed)
28.2lb (12.8kg)
Input Requirements
(per power supply)
Range Line Voltage
90 - 132 VAC,
180 - 264 VAC
Rated Input Current
6 A (at 100 VAC),
3 A (at 200 VAC)
Rated Input Frequency
47 to 63 Hz
Rated Input Power
<550W (at 100 VAC)
550W (at 200 VAC)
BTU Rating
Maximum
1314 BTU/hr (at 100 VAC),
1314 BTU/hr (at 200 VAC)
Power Specifications
To review typical system power ratings use the Power Advisor which is
available via the online tool located at URL:
www.hp.com/go/proliant-
energy-efficient
or
www.hp.com/go/hppoweradvisor
- Click on the system of interest. Example: DL120 G6
- Follow the instructions of the next screens.
Power Supply Output
(per power supply)
Rated Steady-State
Power
400 W (at 100 VAC),
400 W (at 200 VAC)
Maximum Peak Power
430 W (at 100 VAC),
430 W (at 200 VAC)
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change
is 10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).
Non-operating
-30° to 65°C (-22° to 149°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature,
non-condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature,
non-condensing.
Altitude
Operating
3050 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).
QuickSpecs
HP ProLiant DL120 Generation 6
Technical Specifications
DA - 13504 Worldwide QuickSpecs — Version 3 — 12.18.2009
Page 28