Honeywell Optiflex Home Theater Server User Manual


 
2-1
SECTION 2
Mounting, Wiring, and Setup
•••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
Setup Considerations
Mounting Optiflex
Wiring and Setup of Optiflex
•••••••••••••••••••••••••••••••••••••••••••••••••
Setup Considerations
Cameras connected to Optiflex can either be triggered by system events from a Honeywell
Vista control panel, from the voltage triggers provided, or both. Optiflex can also be used
without any triggers at all, if the system is configured to automatically scan the cameras one
at a time, or if the cameras are always on. If using the voltage triggers, refer to the table
below to determine which camera each voltage trigger turns on.
Voltage Trigger Function
1 Captures Video on Camera 1
2 Captures Video on Camera 2
3 Captures Video on Camera 3
4 Captures Video on Camera 4
5 Captures Video on Camera 5
6 Captures Video on Camera 6
7 NTSC Advance
8 Captures Video on All Cameras
If using a Honeywell Vista control panel, the cameras are turned on using Output (relay)
Programming commands in the control panel. To accomplish this, enable a 4204 Relay
Module in the system’s Device Programming Mode as Device Address 12. Then program
eight logical relays and point to the same four physical relays twice, programmed as shown
in the table below, using system events or zones/zone lists as desired to turn on the relays as
shown below. Cameras are turned on through the ECP (Data In and Data Out) connections
(See “Wiring and Setup of Optiflex”) in this section, and the control panel’s Programming
Guide for information on how to program output relays.
4204 Output Command (4204 on ECP Address 12) Function
Relay 1: Turn ON for 2 seconds Captures Video on Camera 1
Relay 2: Turn ON for 2 seconds Captures Video on Camera 2
Relay 3: Turn ON for 2 seconds Captures Video on Camera 3
Relay 1: Continuous Pulse Captures Video on Camera 4
Relay 2: Continuous Pulse Captures Video on Camera 5
Relay 3: Continuous Pulse Captures Video on Camera 6
Relay 4: Continuous Pulse NTSC Advance
Relay 4: Turn ON for 2 seconds Captures Video on All Cameras