25
4
RECEIVE AND TRANSMIT
•Setting output power
➀
Push [DISPLAY] for 2 sec. to select quick set mode.
➁Push [MENU] one or more times to select Q1 RF
POWER.
➂Rotate the main dial to select the desired output.
•Output power is displayed in 11 steps (L, 1–9 and H) but
is continuously selectable.
➃Push [DISPLAY] to exit quick set mode.
•Available power
*Carrier power
•Setting microphone gain
Microphone gain must be adjusted properly so that
your signal does not distort when transmitted.
➀Select SSB or another phone mode.
➁
Push [DISPLAY] for 2 sec. to select quick set mode.
➂Push [MENU] one or more times to select Q2 MIC
GAIN.
•The ALC meter is selected automatically when operat-
ing in SSB mode.
➃While speaking into the microphone adjust the mic
gain so that the ALC meter does not peak past the
ALC zone.
➄Push [DISPLAY] to exit quick set mode.
USB
Q1 RF POWER
Maximum output power is
selected.
PO
S1
5
53792040
10
60dB
Microphone gain is
set to 6.
ALC
S1
123
5379204060dB
USB
Q2
MIC GAIN
ALC
ALC zone
D Meter function
The bar meter in the function display acts as an
S-meter (for relative signal strength, except in WFM
mode) during receive and can be selected for one of
three types during transmit.
➀Select M3.
•Push [DISPLAY] 1 or 2 times when S or G appears.
•Push [MENU] one or more times to select M3.
➁Push [(F-3)MET] one or more times to select the
desired meter function.
•The display indication changes as in the table at right.
D Output power and mic gain
■ Functions for transmit
Note:The SWR meter cannot be used for the 144/430
MHz bands since the meter activates for the [ANT 1] con-
nector only.
BAND SSB/CW/RTTY/FM AM*
HF 5–100 W 4–40 W
50 MHz 5–100 W 4–40 W
144 MHz 2–20 W 2–8 W
DISPLAY
INDICATION
MEASUREMENT
Po
Indicates the relative RF output power.
ALC
Indicates the ALC level. When the
meter movement shows the input signal
level exceeds the allowable level, the
ALC limits the RF power. In such cases,
reduce the microphone gain (see
above).
SWR
Indicates the SWR over the transmis-
sion line.