47
7
SET MODE
■ General
Set mode is used for programming infrequently
changed values or conditions of functions. The IC-
706MKIIG has 2 separate set modes:
quick set mode
and
initial set mode.
D Quick set mode operation
➀While power is ON, push [DISPLAY] for 2 sec.
•Quick set mode is selected and one of its items appears.
•Quick set mode items vary depending on the operating
mode (SSB, FM, etc.) selected.
➁Push [MENU] one or more times to select the
desired item.
•[M-CH] or [Y]/[Z] can also be used.
➂Rotate the main dial to set the values or conditions
for the selected item.
➃Repeat steps ➁ and ➂ to set other items.
➄To exit quick set mode, push [DISPLAY] momentar-
ily.
D Initial set mode operation
➀Push [POWER] for 2 sec. to turn power OFF.
➁While pushing [LOCK] push [POWER] to turn power
ON.
•Initial set mode is selected and one of its items appears.
➂Push [MENU] one or more times to select the
desired item.
•[M-CH] or [Y]/[Z] can also be used.
➃Rotate the main dial to set the values or conditions
for the selected item.
➄Repeat steps ➂ and ➃ to set other items.
➅To exit initial set mode, push [POWER] for 2 sec. to
turn power OFF.
➆Push [POWER] to turn power ON again.
•The conditions selected in initial set mode are now effec-
tive.
[POWER]
[MENU] [LOCK]
Main dial
Item number
Item
Value or
condition
1
MODE SELECT
[DISPLAY EXAMPLE: INITIAL SET MODE]
[M-CH]
[Y]
[Z]
Q1 RF POWER
USB
[POWER]
[MENU]
[M-CH]
[DISPLAY]
Main dial
[Y]
[Z]
Item number
Item
Value or
condition
[DISPLAY EXAMPLE: QUICK SET MODE]
PO
S1
5
53792040
10
60dB