US/Canada J-350/J-360/J-370 Models (60Hz)
240V/50A*
24
0V/60A** 240V/3
0A***
Voltage: 240 VAC 240 VAC 240 VAC
Number of Wires: 3 3 3
Frequency: 60Hz 60Hz 60Hz
Current Draw: 36A 43A 24A
Circuit Breaker: 50A, 2-Pole 60A, 2-Pole 30A, 2-Pole
Important Information:
* In 50A configuration, the heater will no
t operate
while both jets
are running in high speed. This is the factory set
ting. Note:
pump 2 runs only in high speed.
** In 60A configuration, the heater will operate
while both jets pumps
are running in high speed. Note jets pump 2 runs only in high
speed.
*** In 30A configuration, the heater will no
t operate
while either jets
pump is running in high speed. Note: jets pump 2 runs only in high
speed.
US/Canada J-380 Models (60Hz)
2
40V/6
0A* 2
40V/50A** 2
40V/4
0A***
Voltage: 240 VAC 240 VAC 240 VAC
Number of Wires: 3 3 3
Frequency: 60Hz 60Hz 60Hz
Current Draw: 46A 36A 31A
Circuit Breaker: 60A, 2-Pole 50A, 2-Pole 40A, 2-Pole
Important Information:
* In 60A configuration, the heater will operate while any two jets
pumps are running in high speed. This is the factor
y setting
.
** In 50A configuration, the heater will no
t operate
while any two jets
pumps are running in high speed. Note: jet pumps 2&3 run only in
high speed.
*** In 40A configuration, the heater will no
t operate
while any jets
pump is running in high speed. Note: jet pumps 2&3 runs only in
high speed.
5.0 Power Requirements
Jacuzzi Premium spas are designed to provide optimum performance and
flexibility of use when connected to the maximum electrical service as listed
in the tables below. If you prefer, your Jacuzzi Premium dealer can perform
a minor circuit board modification to allow the spa to accept different electri-
cal service. The operational considerations of these modifications are listed in
the footnotes below.
Page 7