4
Preparation
Before replacing the lamp, read all the instructions.
Replacing the lamp
Replacement Lamp Kit:
TS-CL110E
• High-pressure 110 V mercury lamp
Possible causes of shortened lamp life
Turning on/off the TV repeatedly in a short amount of time
Keeping the TV turned on for more than 24 hours consecutively
Use only the specifi ed
Replacement Lamp Kit!
This lamp is for use with JVC
model televisions. Using the
lamp with a different television
or other product could cause a
malfunction and/or damage to
the television or lamp.
If you feel unsure about replacing the lamp yourself
Consult your retailer
LAMP NEEDS TO BE REPLACED.
PLEASE REFER TO THE MANUAL FOR
REPLACEMENT INSTRUCTIONS.
AFTER REPLACING THE LAMP,
PLEASE RESET THE TIMER IN THE
TV MENU.
PRESS OK, IF YOU DO NOT WANT
TO SEE THIS MESSAGE AGAIN.
To make the message disappear
Turn the TV off
Wait until the LAMP
indicator stops
blinking
1
Unplug the TV
2
Wait for at least 1 hour until the lamp has fully cooled
For purchasing the Replacement
Lamp Kit, consult your retailer.
3
The TV uses a lamp to project the picture onto the screen. When the lamp has blown or when the
picture becomes dark, replace the lamp.
Before replacing the lamp, read all the instructions carefully.
Prepare the Replacement Lamp Kit
When the lamp is near to its end...
The following message appears on the screen.
After the usage time of the lamp has reached to 6500 hours, this
message appears every time you turn on the TV.
Remove the lamp cover
Remove the lamp unit
2
Remove the lamp unit
Philips head type screw
driver (cross-head type)
1
Do not drop
the lamp!
If you feel any warmth
near the lamp, DO NOT
TOUCH IT!
Never attempt to replace the lamp with the TV plugged in!
Attempting to replace the lamp with the TV plugged in could lead to a severe electrical
shock.
Never replace the lamp before it has fully cooled!
The lamp becomes extremely hot while in use, which may cause a burn. After turning
off the TV, wait for at least 1 hour.
Loosen Remove
!
!
!
!