14
RS232 (continued)
Following the header, a comma is used to delimit the header from the command. All the commands with their descriptions are
listed below. All the text strings are terminated with a carriage return (0x0d or 13). Maximum command string length is 250
characters.
OPTIONS OR RANGE
(0-2) 0=4x3,1=Letterbox, 2=Anamorphic
(0-170) 128 default
(0-155) 110 default
(0-13) 8 default
(0-220) 128 default
(0-8) [1-8=User, 0=Factory]
(0-1) [0=Normal1=Bypass]
(0-255) 128 default
0=Off
1=100% Color Bars
2=Reverse Color Bars
3=10-step Grayscale
4=Luma Ramp
5=Cb Ramp
6=Cr Ramp
7=Green
8=Red
9=Blue
10=Convergence
11=Active Boarder
12=Multiburst
13=100% Window
14=PLUGE Test Pattern Selection
COMMAND
A#
B#
C#
D#
DVI
EXT
FST
HELP
K#
OFF
ON
P#
PM#
PY
R
ST
T#
TP#
TPHELP
V
X
Y
DESCRIPTION
Input Aspect Ratio – for all sources
Brightness
Contrast
Detail
DVI Input
Pass-through Input
Report Current System Status
Displays full list of commands for this unit
Color
Power OFF
Power ON
Recall Preset
Advanced Color System
PassThru Transcoded Input
RGB input
Report Current Status
Tint
Display Test Pattern Help
Video input
YCrCb input
S-Video input
OPERATION COMMANDS (Used for day-to-day operation)