JVC SR-L910EK VCR User Manual


 
18
PAL
REC
PLAY
FFREW
REVERSE
PAUSE/
STILL
REC
CHECK
STOP/EJECT
COUNT/
CLOCK
TIME
MODE
TIMER
REC
AL/PL
RESET
MENU
VIDEO CASSETTE RECORDER
SHIFT/TRACKING
SET/V.LOCK
RESET
/CANCEL
OPERATE
SR-L910E
OPE. LOCK
ALARM IN
A L 0 0 1 2 0 : 3 0 9
6 9 8
A L 0 0 2 2 1 : 4 4 1 0
6 9 8
A L :
A L :
A L :
A L :
A L :
A L :
A L :
PRESS (AL / PL) TO ALL RESET
PRESS (MENU) TO END
POWER LOSS
P L 0 0 1 2 1 : 3 0 9 / 6 / 9 8
P L 0 0 2 1 7 : 4 4 1 0 / 7 / 9 8
P L :
P L :
P L :
P L :
P L :
P L :
P L :
PRESS (AL / PL) TO ALL RESET
PRESS (MENU) TO END
[SHIFT +/] buttons
[MENU] button
[AL/PL RESET]
button
[SET +/] buttons
4-3 Alarm Input/Power Loss Data Display
The dates and times of up to nine (9) alarm inputs or power losses (failures) can be displayed.
First alarm
Second alarm
Power loss (failure) data screen
First power failure
Second power
failure
Hour
Minute
Year
Turn on the VCR and monitor. Make sure the Stop
mode is engaged.
Press the [MENU] button to display the main menu.
Press the [SHIFT +] or [SHIFT -] button to select
ALARM IN or POWER LOSS.
To display alarm input data, select ALARM IN. To
display power failure data, select POWER LOSS.
Press the [SET +] or [SET -] button to display the
selected data (alarm input or power loss).
When 10 or more alarm input or power loss data
items have been stored, subsequent data will
replace earlier items, beginning from the second
item.
Press the [MENU] button to end menu operation and
restore the normal screen.
Resetting alarm input/power loss (failure) data
When the "AL" (alarm) display is off and the VCR is in
the normal screen mode, press the [AL/PL RESET]
button to reset the alarm input and power loss data
stored in memory.
4-4 Hour Meter Display
Drum rotating time is displayed in the form of an hour
meter. Use this data to schedule maintenance.
HOUR METER
DRUM ON 02345H
PRESS (MENU) TO END
Hour meter screen
Drum rotating time
Operation
Turn on the VCR and monitor. Make sure the Stop
mode is engaged.
Press the [MENU] button to display the main menu.
Press the [SHIFT +] or [SHIFT -] button to select HOUR
METER.
Press the [SET +] or [SET -] button to display the hour
meter (drum rotating time).
Press the [MENU] button to end menu operation and
restore the normal screen.
4 MONITOR ON-SCREEN DISPLAY
Alarm input data screen
Day
Month
19
COUNT/
CLOCK
TIME
MODE
TIMER
REC
AL/PL
RESET
MENU
SHIFT/TRACKING
SET/V.LOCK
RESET
/CANCEL
PAL
MAIN MENU
PROGRAM TIMER
FUNCTION
ALARM IN
POWER LOSS
HOUR METER
CLOCK ADJUST
PRESS (SHIFT, SET)
PRESS (MENU) TO END
A LARM / SENSOR REC MODE
(ALARM REC) OFF
(SENSOR REC) OFF
(TIMER ALARM) ON
(DURATION) 180SEC
(BUZZER) OFF
(TAPE END MODE) STOP
PRESS (SHIFT, SET)
PRESS (MENU) TO END
ON SCREEN MODE
(POSITION) L
UP
PRESS (SHIFT, SET)
PRESS (MENU) TO END
VTR MODE 1
(SHARPNESS) NORMAL
(VIDEO MODE) AUTO
(AUTO REC) OFF
(REC CHECK) MANUAL
(TAPE END MODE) REPEAT
(INDEX SEARCH) OFF
(INDEX AL/SKIP) ALARM
(TAPE END BUZZER) OFF
(WARNING BUZZER) OFF
PRESS (SHIFT, SET)
PRESS (MENU) TO END
VTR MODE 2
(SUMMER TIME) OFF
(TAERMINAL SEL 1) SERIES
(TAERMINAL SEL 2) WARN
(REC REMAIN) OFF
(NOISELESS PLAY) OFF
(CAMERA SW) OFF
(CAM SW WIDTH) 5msec
PRESS (SHIFT, SET)
PRESS (MENU) TO END
5 SETTING OF THE FUNCTION MENU SWITCHES
You can customize the VCR's functions to suit the requirements of your application using on-screen menu's function switches.
Menu function switches are available on four setting screens: ON SCREEN MODE, VTR MODE 1, VTR MODE 2 and
ALARM/SENSOR REC mode. (When the optional SA-K97U RS-232C interface board is installed, the RS-232C
PARAMETER setting screen is also available.)
5-1 Function Menu Switch Setting
Normal screen
[MENU]
button
[MENU]
button
Main menu screen
On-screen mode setting
VTR mode 1 setting
VTR mode 2 setting
[MENU] button
Preparation
5
Connect the VCR's video output connector to the
monitor's video input connector.
5
Turn on the VCR and the monitor. Make sure the Stop
mode is engaged.
Press the [MENU] button to display the main menu.
Press the [SHIFT +] or [SHIFT
] button to select
FUNCTION.
Press the [SET +] or [SET
] button.
[
The ON SCREEN MODE setting screen is
displayed.
Only one menu switch is available in the ON SCREEN
MODE setting screen. This switch (<POSITION>)
allows you to select the screen position of the on-
screen display and to switch it ON/OFF.
Press the [SET +] or [SET ] button to enter the selected
position.
To display another setting screen, press the [SHIFT +/
]
button.
Press the [SHIFT +] button to display the VTR mode 1
setting screen.
Press the [SHIFT
] button to display the alarm/sensor
recording mode setting screen.
[MENU] button
[SHIFT +] button
[SET ] button [SET +] button
[SHIFT ] button
[SET
+/-]
buttons
When the optional SA-K97U RS-232C interface
board is installed, the RS-232C PARAMETER
setting screen is also available.
Select an item with the [SHIFT +/-] buttons.
Enter the selected values with the [SET +/-] buttons.
Alarm/sensor recording
mode setting
The VTR mode 1, VTR mode 2 and alarm/sensor
recording mode setting screens include several menu
switches.
Press the [SHIFT +] or [SHIFT
] button to select the
item you want to set.
When the cursor arrow reaches the last item (bottom of the
screen) pressing the [SHIFT +] button advances the
display to the next menu switch setting screen.
e.g.: (WARNING BUZZER)
[
(SUMMER TIME)
When the cursor arrow is at the first item (top of the
screen), pressing the [SHIFT -] button will change the
display to the previous menu switch setting screen.
e.g.: (SHARPNESS)
[
(POSITION)
Press the [SET +] or [SET
] button to enter the selected
value.
To set more than one menu switch, repeat steps
6 and 7.
End menu switch setting.
Press the [MENU] button twice.
[
The normal screen is restored.
Set values are stored in the VCR's memory. This
data is retained even when the power is turned off.