KVH Industries TracVision L2 Satellite TV System User Manual


 
Azimuth CCW Step
Function: commands a 0.1 deg CCW manual step in azimuth
angle
Command: 4
Argument: none
Response: echoes the command
Elevation UP Step
Function: commands a 0.1 deg UP manual step in elevation
angle
Command: 8
Argument: none
Response: echoes the command
Elevation DOWN Step
Function: commands a 0.1 deg DOWN manual step in elevation
angle
Command: 2
Argument: none
Response: echoes the command
F. 3 Operational Commands
Idle Mode
Function: halts active tracking and conical scan, then enters
idle mode
Command: HALT
Argument: none
Response: echoes the command
Current Cable Wrap Angle
Function: sets or reports current cable wrap angle, defined as
0º (CCW limit) to 700º (CW limit); the value is
expressed as 0000-7000 with an implied decimal
Command: WRAPANGLE,xxxx
Argument: the desired cable wrap angle setting
Response: Wrap Angle = xxxf
F-3
Maintenance Port Parser Commands
54-0195 Rev. A
Table F-3
Operational Commands