Maxtor 16Channel Stand Alone DVR DVR User Manual


 
32
EVENT SERVER SETUP
IP ADDRESS 192.168.001.072
IP PORT 09988
EVENT SERVER TYPE OFF
INTERVAL ---
EVENT GMT TYPE GMT+00:00
SELECT : ▲▼, CHANGE VALUE : + -
(5) EVENT SERVER SETUP :
IP ADDRESS : IP Address of PC that executes
EVENT SERVER PROGRAM.
IP PORT : PORT of PC that executes
EVENT SERVER PROGRAM
EVENT SERVER TYPE :
It is the way to transmit data to SERVER
By "OFF", "EVENT", "MINUTE“,
In case Event happens from DVR.
"EVENT“: It transmits by the number of EVENT.
"MINUTE“: It transmits each scheduled time.
INTERVAL: If EVENT SERVER TYPE is "EVENT"
User can select from 1~512.
If EVENT SERVER TYPE is "MINUTE“, User can select from 1 ~ 60 mins.
EVENT GMT TYPE : User can set currently installed location(DVR) of GMT.
3) PANTILT SETUP
It is to set parameters for PTZ camera connected to DVR unit. DVR unit already includes all
protocols of well-known PTZ cameras like PELCO D type PTZ camera, and user just select MODEL
and set other parameters to control this PTZ cameras, using operation buttons on the front panel of
DVR.
2) RS-232C SETUP
User can control the DVR via RS-232C port.
Connect DVR to PC via RS-232C port and control
DVR using keyboard of PC.
This function is mainly for programmer who
wants to control DVR as part of many devices
connected to PC system, as in SI project.
RS-232C SETUP
SPEED
LENGTH
STOP BIT
PARITY
115200
8
1
NONE
SELECT : ▲▼, CHANGE VALUE : + -
PANTILT SETUP
COMMAND SETTING PTZ camera set
SPEED SETTING PTZ speed set
SELECT : ▲▼, & [ENTER]
COMMAND SETTING
CHANNEL
MODEL
PTZ ID
BAUDRATE
CMD DELAY
COMMAND
LENGTH
CODE
01
PELCO-D
000
2400 BPS
1 MSEC
PAN/TILT STOP
07
FF 00 00 00
00 00 00 00
SELECT : ▲▼, CHANGE VALUE : + -
(1) CHANNEL : Select channel
(2) MODEL : Select camera model (protocol type) per each channel
(3) PTZ ID : Select ID
(4) BAUDRATE : Select data transmission speed
(5) CMD DELAY : Select command delay time
CHAP. 5 Set Up