Mitsubishi Electronics A1SJ61QBT11 Home Theater Server User Manual


 
A - 9
7.3 Name of Each Part and Settings ............................................................................................................7- 4
7.4 Checking Module Condition (Hardware Test)........................................................................................7- 8
7.5 Module Wiring with CC-Link Dedicated Cable.......................................................................................7-10
7.6 T-Branch Connection with the CC-Link Dedicated Cable .....................................................................7-11
7.6.1 T-Branch system configuration........................................................................................................7-11
7.6.2 T-Branch communication specifications list ....................................................................................7-12
7.7 Switch Settings........................................................................................................................................7-14
7.7.1 Station number setting
(master station, local station, standby master station, and remote station)...................................7-14
7.7.2 Mode setting.....................................................................................................................................7-16
7.7.3 Transmission speed setting.............................................................................................................7-16
7.7.4 Condition setting...............................................................................................................................7-17
7.8 Checking the Connection Condition (Line Test) ....................................................................................7-18
7.8.1 Checking connection and communication status with remote station/local station/standby master
station (line test 1) ............................................................................................................................7-18
7.8.2 Checking communication status with specific remote station/local station/standby master station
(line test 2)........................................................................................................................................7-20
7.9 Checking Parameters (Parameter Confirmation Test) .......................................................................... 7-22
8. PROGRAMMING ............................................................................................................................8- 1 to 8-22
8.1 Precautions When Programming ...........................................................................................................8- 1
8.2 Precautions for Registering Parameters to E
2
PROM ...........................................................................8- 3
8.2.1 Target module and versions ............................................................................................................8- 3
8.2.2 Precautions.......................................................................................................................................8- 3
8.2.3 Program for registering parameters to E
2
PROM............................................................................8- 4
8.3 Programming Procedure.........................................................................................................................8- 6
8.3.1 Communication between the master station and remote I/O station ............................................. 8- 6
8.3.2 Communication between the master station and remote device station .......................................8- 7
8.3.3 Communication between the master station and local station .......................................................8- 8
8.3.4 Communication in a compound system .......................................................................................... 8-10
8.4 Link Special Relay/Register (SB/SW) ....................................................................................................8-12
8.4.1 Link special relay (SB) .....................................................................................................................8-12
8.4.2 Link special register (SW)................................................................................................................8-16
9. COMMUNICATION BETWEEN THE MASTER STATION AND THE REMOTE
I/O STATION...................................................................................................................................9- 1 to 9-12
9.1 System Configuration.............................................................................................................................. 9- 1
9.1.1 Setting of the master station ............................................................................................................9- 2
9.1.2 Setting of the remote I/O station......................................................................................................9- 3
9.2 Creating a Program.................................................................................................................................9- 4
9.2.1 Program for parameters...................................................................................................................9- 4
9.2.2 Communication program..................................................................................................................9- 7
9.3 Performing the Data Link........................................................................................................................9-10
9.3.1 Confirming the operation by LED display........................................................................................9-10
9.3.2 Confirming the operation by the program........................................................................................9-11