Mitsubishi Electronics WD-62528 Flat Panel Television User Manual


 
MODEL: WD-52527 / WD-52528 / WD-62527 / WD-62528
Page 29
4. Adjustment Selection
Use the “VIDEO” button to select a specific elecrtrical ajustment, “1 HPOS” or “2 VPOS”.
5. Adjusting Data
After selecting an adjustment item, use the “UP” and “DN” buttons to change adjustment data.
• If the “UP” button is pressed, the adjustment data increases.
• If the “DN” button is pressed, the adjustment data decreases.
6. Saving Data
Press “ENTER” to save the adjustment data in memory.
The display characters go red for approximately one second in this step.
Note: If the circuit adjustment mode is terminated without pressing “ENTER”, changes in adjustment data are
not saved.
7. Terminating the circuit adjustment mode
Press the “MENU” button on the remote hand unit twice to terminate the adjustment mode.
Note: The adjustment mode can be also terminated by turning the power off.
Transferring Data
1) Enter the Service Adjustment Mode ... Press “MENU-2-4-5-7”
2) Press “0” when in the Service Mode ... Three choices appear at the top of the screen.
3) Use the UP & DN keys to highlight the desired choice, the Press “ENTER”
Data Transfer
"MENU-2-4-5-7-0"
Display Description
Restore Back Up Resets data to factory values
Upload Terminal Data Not used
Down load WB data to FMT Use after replacing Engine PWB-FORMAT