MODELS: WD-60735 / WD-60C8 / WD-65735 / WD-65736 / WD-65835 / WD-65C8 / WD-73735 /
WD-73736 / WD-73835 / WD-73C8
Page 28
SERVICE ADJUSTMENTS
There are 3 Service Adjustments required in these models:
Electrical Adjustments (there are no mechanical adjustments)
• Horizontal Centering
• Vertical Centering
• 16 Point Keystone Alignment
• Letterbox Geometry
• 4:3 Geometry
Measuring Equipment and Jigs
• No additional Test Equipment is required.
• Remote Control
Test Signal
An internally generated Test Signal is used. No additional external signals are required.
Circuit Adjustment Mode
On these models, the Circuit Adjustment Mode is used for:
• Test Signal activation
• Horizontal and Vertical Centering
• Manual-alignment of keystone geometry
• The following adjustments may only be performed using the remote control.
Horizontal and Vertical Centering Adjustment
1. Activating the Adjustment Mode
1. Press the “MENU” button on a remote hand unit. (The “MENU” display will appear.)
2. Press the buttons “2”, “4”, “5” and “7” in that order. (Adjustment mode will appear.)
If not changed to the adjustment mode press “EXIT” and repeat steps 1 and 2.
2. Test Signal Activation (for H and V position adjustment)
When in the Circuit Adjustment mode, press “PLAY” to activate the internal test patterns, then use FAST
FORWARD (ff) and REWIND (ee) to select the pattern shown below. This pattern is used for H&V
electrical centering adjustments.
Centering Test Pattern