NEC GT2000, GT2000R Projection Television User Manual


 
E-74
Cleaning Or Replacing The Filter
The air-filter sponge keeps the inside of the MultiSync GT2000/
GT2000R LCD Projector free from dust or dirt and should be
cleaned after every 100 hours of operation (more often in dusty
conditions). If the filter is dirty or clogged, your projector may
overheat.
NOTE: Clean your filter after every 100 hours of operation.
CAUTION
Turn off the main power and unplug the projector before
replacing the filter.
Only clean the outside of the filter cover with a vacuum
cleaner.
Do not attempt to operate the projector without a filter
cover.
Your LCD projector will not operate unless the filter cover
is installed correctly.
To clean the air-filter:
Vacuum the filter through the filter cover.
To replace the air-filter:
1. Remove the filter cover by pushing up on the catch of the
cover until you feel it detach.
2. Reinstall the new filter cover.
NOTE: Do not detach the sponge from the filter cover. Do not
wash the filter cover with soap and water. Soap and
water will damage the filter membrane.
Before replacing the filter cover, remove dust and dirt
from the projector cabinet. Keep out dust and dirt
during filter replacement.
Remote Control Battery Installation
AC IN
MENU
SELECT
ENTER
STATUS
ZOOM
FOCUS
POWER
ON / OFF
-
+
-
+
-
+
AC IN
MENU
SELECT
ENTER
STATUS
ZOOM
FOCUS
POWER
ON / OFF
-
+
-
+
-
+
Installing the Remote Control Batteries
When it comes time to replace the batteries, two "AAA" type
will be required.
1. Press and open the cover.
2. Align the batteries according to the (+) and (-)
indications inside the case.
3. Replace the cover.