77
Displaying Supplementary Status Information
Chapter 4 Menu Settings
Displaying
Supplementary Status
Information
When you set the SUB STATUS menu item (see page 62)
to other than OFF, you can view supplementary status
information on the monitor screen below the operating
mode display area.
The following items of supplementary status information
are displayed depending on the setting of the SUB
STATUS menu item.
The following tables show the on-screen indications of
supplementary information and their meaning.
In each table, the indications given in brackets such as
[ASM] are the indications displayed when the SUB
STATUS menu item is set to ALL.
For the display format when ALL is selected, see the next
section.
Setting of SUB
STATUS menu item
Items of supplementary
information displayed
EDIT PRESET Editing mode settings made on the
editing control unit
TC MODE Operating mode of the internal time
code generator
REMAIN Remaining capacity of the tape
AUDIO MIXING Setting for input audio mixing
ALL All of the above items
When the SUB STATUS menu item is set to EDIT
PRESET:
On-screen
indication
Meaning
ASM
[ASM]
Assemble editing mode
INS V A1234 TC
[V1234T]
INS: Insert editing mode
V A1234 TC: Channels or signals
selected for insert editing
V: Video
A1234: Audio 1, 2, 3, 4
TC: Time code
TCR
PLAY
00:04 47
.
07
LOCK
.
IN V A1 34
2
TCS
Supplementary status information
When the SUB STATUS menu item is set to TC MODE:
On-screen
indication
Meaning
INT PRST FREE
[IP F]
The internal time code generator is
operating in FREE RUN mode.
INT PRST REC
[IP R]
The internal time code generator is
operating in REC RUN mode.
INT REGEN-T&U
[IRTU]
The internal time code generator is in
synchronization with the playback
time code (LTC) read from tape.
EXT LTC-T&U
[ELTU]
The internal time code generator is in
synchronization with the external time
code (LTC) input to the unit and is
generating the same time code value
and user bit value as those of the
external time code (regeneration).
EXT VITC-T&U
[EVTU]
The internal time code generator is in
synchronization with VITC present in
the external video signal input to the
unit and is generating the same time
code value and user bit value as
those of the external time code
(regeneration).
EXT QSDI-T&U
[EQTU]
The internal time code generator is in
synchronization with the external time
code input to the unit via the SDTI
(QSDI) interface and is generating the
same time code value and user bit
value as those of the external time
code (regeneration).
EXT QSDI. V-T&U
[EQTU]
The internal time code generator is in
synchronization with the external
VITC input to the unit via the SDTI
(QSDI) interface and is generating the
same time code value and user bit
value as those of the external time
code (regeneration).
EXT DVIN-T&U
[EDTU]
The internal time code generator is in
synchronization with the external time
code input to the unit via the i.LINK
(i.DV IN) interface and is generating
the same time code value and user bit
value as those of the external time
code (regeneration).
EXT DVIN. V-T&U
[EDTU]
The internal time code generator is in
synchronization with the external
VITC input to the unit via the i.LINK
(i.DV IN) interface and is generating
the same time code value and user bit
value as those of the external time
code (regeneration).
When the SUB STATUS menu item is set to REMAIN:
On-screen
indication
Meaning
REMAIN 184 min Remaining capacity of the tape in
minutes.
When the remaining capacity has not
been calculated, “REMAIN --- min”