Panasonic FP0 Series Universal Remote User Manual


 
FP0 Expansion Units
Choose the number of I/O points to suit the application
5
Combinations with transistor output type – Examples
=
+
=+
=+
=+
=+
+
+
=++
=++
= +++
+
= +++
48
Input 24 Output 24
32
Input 16 Output 16
16
Input 8 Output 8
16
Input 8 Output 8
32
Input 16 Output 16
64
Input 32 Output 32
32
Input 16 Output 16
32
Input 16 Output 16
80
Input 40 Output 40
32
Input 16 Output 16
32
Input 16 Output 16
16
Input 8 Output 8
16
Input 8 Output 8
32
Input 16 Output 16
32
Input 16 Output 16
96
Input 48 Output 48
32
Input 16 Output 16
32
Input 16 Output 16
32
Input 16 Output 16
16
Input 8 Output 8
32
Input 16 Output 16
32
Input 16 Output 16
112
Input 56 Output 56
32
Input 16 Output 16
32
Input 16 Output 16
32
Input 16 Output 16
16
Input 8 Output 8
()
Total number
of I/O points
()
Control unit
()
Expansion unit 1
X20~/Y20~
()
Expansion unit 2
X40~/Y40~
()
Expansion unit 3
X60~/Y60~
=+++
16
Input 8 Output 8
128
Input 64 Output 64
32
Input 16 Output 16
32
Input 16 Output 16
32
Input 16 Output 16
32
Input 16 Output 16
Digital I/O Units
Relay output type Input only type
Transistor output type
Analogue I/O Units Thermocouple and RTD Units Networking Units
PROFIBUS
FP0-DPS2
(DP Slave)
MEWNET-F
FP0-IOL
(MEWNET-F Slave)
S-Link CPU
FP0-SL1
(S-LINK Master)
FP0-E16RSA FP0-E8XA FP0-E16XAFP0-E8RSA
FP0-E8YRSA
8 points
Input
8 points
16 points
Input
16 points
8 points
Input
4 points
Option:
Output 8 points
Output
4 points
16 points
Input
8 points
Output
8 points
FP0-E8YPA (PNP)
FP0-E8YTA (NPN)
FP0-E16YPA (PNP)
FP0-E16YTA (NPN)
FP0-E16PA (PNP)
FP0-E16TA (NPN)
FP0-E32PA (PNP)
FP0-E32TA (NPN)
8 points
Output
8 points
16 points
Input
8 points
Output
8 points
16 points
Output
16 points
32 points
Input
16 points
Output
16 points
8 points3 points 4 points 4 points
Input
8 points
FP0-A80A
Input (12 bit):
ȗ 10V, 0 5V,
0 20mA
Output (12 bit):
ȗ 10V, 0 20mA
4 20mA
ȗ 10V
ȗ 10V, ȗ 100mV
0 5V, 0 20mA
Input
2 points
Output
1 points
Output
4 points
Output
4 points
FP0-A21A FP0-A04I FP0-A04V
4 points
Input
4 points
FP0-TC4 FP0-TC8
8 points
6 points
Input
6 points
K, J, T, R type thermocouples can
be used
Resolution: 0,1°C
Accuracy: 0,8°C (R type: 3°C)
Temperature range:
-100 to 1500°C
Input
8 points
FP0-RTD6
Pt100, Pt1000,
NI1000
Temperature
range -200
to 500ºC
FP0_broschüre_4093 euen0904 15.10.2004 8:42 Uhr Seite 5
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
10/2004