Parker Hannifin acr-motion max api users guide Home Theater Server User Manual


 
API Users Guide I/O Map - 21
152 T Strobe Set By ACR-MOTIONMAX when a T Code has been Sent to be serviced by
AcroBasic
153 Tool Change Active Set by ACR-MOTIONMAX DLL to Signal M6 Sub needs to do a change
154 Tool Change Done Set By AcroBasic in M6 Code to signal a tool change has finished ok
155 Z @ T change Position Set By AcroBasic to Signal that Z is at the Tool change Position
156 Tool Seek Active Set in AcroBasic T Strobe Code to Signal that Magazine is Moving
157 Tool Seek Done Set by AcroBasic to Signal that the seek operation is complete
158 Tool Seek Direction Set By ACR-MOTIONMAX to Signal bi-directional Magazine direction to Move
159 Tool Seek Speed Set By AcroBasic for Magazines that have Slow Down Capabilities
160 MPG Enabled Set By AcroBasic to Signal ACR-MOTIONMAX that Pendant is Enabled
161 MPG X Select Set by AcroBasic to Signal ACR-MOTIONMAX that Axis is under Pendant Control
162 MPG Y Select Set by AcroBasic to Signal ACR-MOTIONMAX that Axis is under Pendant Control
163 MPG Z Select Set by AcroBasic to Signal ACR-MOTIONMAX that Axis is under Pendant Control
164 MPG 4 Select Set by AcroBasic to Signal ACR-MOTIONMAX that Axis is under Pendant Control
165 MPG 5 Select Set by AcroBasic to Signal ACR-MOTIONMAX that Axis is under Pendant Control
166 X.1 Mode Select Set by AcroBasic to Signal ACR-MOTIONMAX that X.1 Mode is selected for
Pendant Moves
167 X1 Mode Select Set by AcroBasic to Signal ACR-MOTIONMAX that X1 Mode is selected for
Pendant Moves
168 X10 Mode Select Set by AcroBasic to Signal ACR-MOTIONMAX that X10 Mode is selected for
Pendant Moves
169 X100 Mode Select Set by AcroBasic to Signal ACR-MOTIONMAX that X100 Mode is selected for
Pendant Moves
170 X Home Done Set by AcroBasic to Signal ACR-MOTIONMAX that Axis has been Referenced
171 Y Home Done Set by AcroBasic to Signal ACR-MOTIONMAX that Axis has been Referenced
172 Z Home Done Set by AcroBasic to Signal ACR-MOTIONMAX that Axis has been Referenced
173 4 Axis Home Done Set by AcroBasic to Signal ACR-MOTIONMAX that Axis has been Referenced
174 5th Axis Home Done Set by AcroBasic to Signal ACR-MOTIONMAX that Axis has been Referenced
175 Magazine Ref Done Set by AcroBasic M18 to Signal ACR-MOTIONMAX that Magazine has been
Referenced
176 Gear Change Active Set by AcroBasic when effecting a Gear change
177 Gear Change bit 0 Set by ACR-MOTIONMAX to signal which Gear has been Requested (is a binary
code)
178 Gear Change bit 1 Set by ACR-MOTIONMAX to signal which Gear has been Requested (is a binary
code)
179 Gear Change bit 2 Set by ACR-MOTIONMAX to signal which Gear has been Requested (is a binary
code)
180 Spindle Direction Bit Set by AcroBasic to signal Spindle direction is for M3/M4 outputs 1 fwd 0 rev
181 0 Speed Arrival bit Set by AcroBasic to Signal that Spindle is at rest
182 Speed Arrival bit Set by AcroBasic to signal that spindle is running at the commanded speed
183 Orient Complete Set By AcroBasic to signal that Spindle is at the orient Position
184 Spindle Enable Set by ACR-MOTIONMAX to signal that the spindle is Enabled
185 Rigid Tapping Active Signal will be 1 when the ACR-MOTIONMAX Control is Rigid Tapping
186 Tapping Active Signal will be 1 when ACR-MOTIONMAX is running a Tapping cycle
187 4th Axis Present Set by AcroBasic to ACR-MOTIONMAX informing control of 4th axis presence
188 4th Axis Clamped Set by AcroBasic to ACR-MOTIONMAX signaling that 4th Axis is locked
189 Contouring Set by ACR-MOTIONMAX to signal that a contouring mode is active
190 SpindleRunning Set in AcroBasic to form logic to turn Spindle back on if paused
191 Reserved
192 Over Travel Active Set by AcroBasic to ACR-MOTIONMAX of an existing OverTravel
193 EnableVirtualEstop Set to Allow Virtual Estop Button on GUI
194 V Estop Status Status Signal used by ACR-MOTIONMAX of VEstop
195 Reserved for future use
196 Reserved for future use
197 Reserved for future use
198 Reserved for future use