Pelco C454M-C Cable Box User Manual


 
20 Pelco Manual C454M-C (1/98)
3.2.3 Heater/Blower Kit Field Installation
The kits are shipped partially assembled, to complete assembly and to install the
heater/blower kit perform the following steps:
1. Place the fan over the four (4) unused internally threaded standoffs located on
the back plate (refer to Figure 11). Note the arrow indicating the air flow direc-
tion of the fan, installing with arrow pointing “away” from back plate.
2. Place the heater assembly over the fan aligning the four (4) holes in the plate
with the holes in the fan and the standoffs.
3. Install the four (4) #6 lock washers and screws through the plate and the fan
threading the screws into the standoffs.
4. Mounting through one hole of the thermostat mounting tab, attach the thermo-
stat to the standoff of the terminal block on the end nearest the fan using the 6-
32 x 3/8" screw (see Figure 11).
5. Connect the terminated wires to the terminal block as shown in Figures 3
through 6 depending on back box configuration.
3.3 DOME DRIVE INSTALLATION
Back box installation is now complete. Proceed with the installation of the dome
drive or fixed mount unit. Refer to the manual provided with the dome drive or fixed
mount for further installation instructions.