5.0 SPECIFICATIONS
ELECTRICAL
Enclosure Back Box
Input Voltage: 24 VAC or 120 VAC
Power Requirements
Receiver/Driver: 48 vA for 24 VAC and 120 VAC dome drives
Blower
continuous duty: One (1) at 30 cfm, 1.92 watts, 24 VDC
One (1) at 33 cfm, 6.7 watts, 120 VAC 60 Hz
One (1) at 27 cfm, 8.9 watts 230 VAC 50 Hz
Heaters
24 VAC: 120 watts total
120 VAC: 135 watts total
230 VAC: 105 watts total
Thermostatically controlled; activates ON at 40°F (4.4°C) and
OFF at 60°F (15.56°C)
Power cord: Not supplied; use 3-wire grounded, 18 Awg minimum for 120 or
230 VAC supply input
Power cable: Not supplied: must conform to local and national electrical
codes
GENERAL
Enclosure
Environment: Indoor or outdoor (depending on model ordered)
Dimensions: See Figures 12 and 13
Construction
Back box: Aluminum
Cap: Aluminum
Bezel: Aluminum
Trim Ring: ABS/aluminum
Finish: The following are standard colors; consult factory for optional
colors
Outdoor
Pendant Light gray
Indoor
Suspended/
Hard Ceiling White (back box) and eggshell white (faceplate, trim ring and
bezel)
Pendant Black
Temperature Range
Indoor models: 32° to 120°F (0° to 48.89°C)
Outdoor models: -10° to 120°F (-23.33° to 48.89°C)
(Design and product specifications subject to change without notice.)
NOTE:
It is not recommended using
24 VAC in applications requiring heat-
ers/blower because of the excessive
current draw that may exceed Class
2 transformer applications.