Perle Systems C-10GT-XFPH TV Converter Box User Manual


 
Perle C/CM-10GT Media Modules Installation Guide
10
AUTO-Config Jumper (CM models
only)
The Auto-Config jumper is located on the outer edge, at the
midpoint of the module. Jumper the top and middle pin to select
Auto mode. Jumper the middle and bottom pin to select SW mode.
AUTO: When set to Auto the module will, at power-up, check its
internal flash memory to see if configuration information has been
downloaded to it from a management module. If so it will use this
configuration as its running configuration. If there is no
configuration in flash it will read the settings of the DIP switches
and use those as its running configuration.
SW: When set to SW (Switch), the module will, at power-up, read
the settings of the DIP Switches and use those as its running
configuration. It will ignore any configuration information in its flash
memory.
NOTE: The default jumper setting is AUTO