RAD Data comm RSD-20 Cable Box User Manual


 
2.5 SYSTEM SYNCHRONIZATION AND CLOCK DISTRIBUTION
2.5.1 RSD-20/V.35
Four alternatives are available for synchronization of the system:
a)Main channel modem timing signals.
b) RSD-20 internal clock.
c) Sub-channel 1 modem timing signals.
d) Any sub-channel modem timing signals. For this the optional buffer is required.
2.5.1.1 Synchronization on Main Channel Modem Clock
a) Main channel modem strapped to internal clock.
b) DCEs attached to sub-channels are strapped to external clock.
c) RSD-20 bit rate setting is ignored (bit rate is determined by main channel modem clock).
RSD-20
DCE
INT. CK
DCE
EXT. CK
DTE
TX. CLK
TX. CLK
EXT. CLK
SUB DTE
MAIN
DTE
SUB DCE
Figure 2.4
Synchronization on Main Channel Modem’s Clock
RSD-20 OPERATOR'S MANUAL INSTALLATION
2.5