11
ALARM SETUP
[BUZZER]
BUZZER DWELL 5SEC
VIDEO LOSS ALARM ON
MOTION ALARM OFF
EXTERNAL ALARM ON
[RELAY]
VIDEO LOSS ALARM ON
MOTION ALARM ON
EXTERNAL ALARM ON
EXTERNAL SENOR SETUP
ALARM DISPLAY MODE OFF
EXIT
EXTERNAL SENSOR SETUP
CHANNEL-1 OFF
CHANNEL-2 NORMAL-OPEN
CHANNEL-3 NORMAL-CLOSE
CHANNEL-4 OFF
EXIT
5. ALARM SETUP
Press ▲ or ▼ key on "ALARM SETUP" & ◄ or ►
to enter:
Use the ▲ or ▼ button to select items.
Press the ◄ or ► button to confirm the
selection.
Press MENU to go back to SETUP MENU.
[BUZZER]
1. BUZZER DWELL 1/2/3 to 30 SEC & CONT
Use ◄ or ► button to set the dwell time for buzzer issue occur. There are a total of
31 periods you can choose from 1 to 30 seconds or "CONT" for constantly.
2. VIDEO LOSS ALARM ON/OFF
Use ◄ or ► button to select video loss alarm function on or off.
3. MOTION ALARM ON/OFF
Use ◄ or ► button to switch function on or off when motion occur.
4. EXTERNAL ALARM ON/OFF
Use ◄ or ► button to switch function on or off when external alarm occurs.
[RELAY]
1. VIDEO LOSS ALARM ON/OFF
Use ◄ or ► button to switch video loss alarm function form relay box.
2. MOTION ALARM ON/OFF
Use ◄ or ► button to switch motion alarm function form relay box.
3. EXTERNAL ALARM ON/OFF
Use ◄ or ► button to switch external alarm function form relay box.
EXTERNAL SENOR SETUP
Use the ▲ or ▼ button to select channel.
Press the ◄ or ► button to change alarm
type.
Press MENU to go back pervious menu.
Each channel with 3 types for selection:
1. OFF
2. NORMAL-OPEN (DEFAULT)
3. NORMAL-CLOSE
ALARM DISPLAY MODE ON/FF
During recording & full channel mode, if ALARM DISPLAY MODE is ON, system
would switch to the ALARM or MOTION channel and the period depend on
ALARM
RECORD DWELL.